Seth was great. Very professional. diagnosed the problem quickly and set up the follow up repairs and parts for us.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for plain city, oh

Graham M.

Graham M. Job Checkin

upon arrival inspected system and found blower motor would not operate. checked capacitor it was 7.9 replaced with fresh 10 blower started but angrily. informed homeowner blower should be replaced, quote was approved replaced motor and test ran system. no further concerns post repair unit is heating adequately


Nate G.

Nate G. Job Checkin

Common drain for humidifier and dehumidifier clogged again Put drain treatment in the dehumidifier drain, changed the humidifier water panel and put drain treatment on the top of the water distributor panel, also put drain treatment in the drainline itself Curious the water panel was so degraded in just over a month. Suspect water quality issues being a contributing factor.


Brandon P.

Brandon P. Job Checkin

Google Nest thermostat is not properly controlling the humidifier. Confirmed proper wiring and that humidifier shuts off when furnace is powered off. This eliminates the possibility of tne wiring, or humidifier solenoid valve being the issue. Thermostat is powering humidifier when humidity is satisfied. Humidity set point of 45% and thermostat is still powering humidifier when it is reading 48%. Thermostat will need replaced. Japinder will replace the thermostat himself. Westin Air recommends Fresh Air Corps for duct work cleaning.

Google Nest thermostat is not properly controlling the humidifier. Confirmed proper wiring and that humidifier shuts off when furnace is powered off. This eliminates the possibility of tne wiring, or humidifier solenoid valve being the issue. Thermostat is powering humidifier when humidity is satisfied. Humidity set point of 45% and thermostat is still powering humidifier when it is reading 48%. Thermostat will need replaced. Japinder will replace the thermostat himself. 

Westin Air recommends Fresh Air Corps for duct work cleaning. Google Nest thermostat is not properly controlling the humidifier. Confirmed proper wiring and that humidifier shuts off when furnace is powered off. This eliminates the possibility of tne wiring, or humidifier solenoid valve being the issue. Thermostat is powering humidifier when humidity is satisfied. Humidity set point of 45% and thermostat is still powering humidifier when it is reading 48%. Thermostat will need replaced. Japinder will replace the thermostat himself. 

Westin Air recommends Fresh Air Corps for duct work cleaning.

Graham M.

Graham M. Job Checkin

Hookup aid tool and inspect system for faults, found 4 high pressure 999 hot water limit and 4 system resets. Reset faults and informed homeowner of high pressure likely being sourced from dirty filters from previous owners. Inspect refrigerant pressures and loop temps loop pressure low at 5psi pumped up to 40 psi with house water. No concerns at this time humidifier clean and on filter clean.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on high efficiency Carrier furnace running in great condition. 20x25x4 air filter in decent condition. Filter is currently in backwards. Make sure to insert filter in correct direction on next filter change. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace running in great condition. 20x25x4 air filter is new today. #35 humidifier pad in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode. Dehumidifier is disabled for Winter time. Furnace and humidifier are operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace running in great condition. Air filter and humidifier pad in good condition. Clean flame sensor and check ignitor ohms. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode test. Systems are operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Replace damaged blower wheel. Parts under warranty, labor is not. Finish test run of heating PMI.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Carrier high efficiency furnace running in great condition. 20x25x4 air filter is new today. Humidifier pad in good condition and damper opened. Confirmed water is on. Humidifier is operating properly. On furnace, clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter. Humidifier is operating properly. Humidity level issues are a combination of low outdoor temperature and being supplied with cold water. Due to lower cold water temperature, the Humidifier is not able to evaporate a sufficient amount compared to using hot water. System is supplied with cold water as water supply valve being used was installed by plumbers during construction. I


Brandon P.

Brandon P. Job Checkin

Upon arrival, David mentioned a clicking noise coming from the furnace. Inspection shows that blower wheel blades has loosened from the center wheel. Blower wheel blades are skipping on the center wheel causing the noise. Blower wheel will need replaced. Performed cleaning portion of preventative maintenence inspection. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Replace #35 water panel in humidifier and set water flow. 20x25x4 air filter in decent condition. Check again in 1-2 months. Test unit in heating mode from thermostat. Did not check temperature rise as an accurate reading is not possible with current faulty blower wheel.


Jason D.

Jason D. Job Checkin

Closed all but 1 register in the basement Closed 4 registers on the 1st floor Closed 3 bathroom and 1 laundry register on the 2nd floor Was able to increase air flow to both heat runs in the master by 3 foot FPM. Also filter was dirty, told Nick to change this asap Sold him a service agreement


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2018 Trane XR95 high efficiency gas furnace running in good condition. 20x25x1 air filter in new condition. Air filter is slightly smaller than what can fit as the current filter is 0.25 inches shorter on each side. This is contributing to the filter being pulled in by blower. Recommend getting air filter with the actual size of 20x25x1. Humidifier pad is in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Test run in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier operation tested from thermostat. No issues with furnace or humidifier were found. Systems are operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 new today Clean flame sensor Inspect burners - clean no concerns Ohm test igniter: 53.2 Inspect wiring for loose connection and/or hot spots - none found Check humidifier pad: new today Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 4.09 Check amp draw on inducer motor:0.65 Check delta T - 54° Furnace is in optimal running conditions


Brandon P.

Brandon P. Job Checkin

Replace electrode wires Replace steam canister Clean unit and test run.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on two Trane high efficiency gas furnaces running in great condition. 20x25x4 air filters are in good condition. Basment system humidifier pad in clean condition. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation traps and drain lines. Run test units in both stages of heating. Both are operating properly and within specs for temperature rise, and blower and inducer motor amp draw. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Test ran systems in geothermal heating aswell with no issues found or suspected. All are operational and ready for Winter. Water leak in unfinished part of basement near hot water generator tank is suspected to be from the Radon pipe as there is no sign of leaks from the tank or lines attached.