Seth was great. Very professional. diagnosed the problem quickly and set up the follow up repairs and parts for us.
Inspected air conditioner and found no issues with the operation of unit. Coil has been very badly damaged has a flat spot and exposed copper. Full Copper coil is more expensive than a new ac unit with coil. Ac will have to be replaced per Adam
Cooling preventative maintenance performed Check filter -20x25x1 new today owner supply Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD -45+5 @ 43+1.5 new today 45+5 Check OD fan Amp - 1.07 Check compressor Amp - 11.81 Verify pressures and HP-SC/LP-SH 312/13°\117/10° Delta T - 20.8° The Air handler and AC are in optimal running conditions.
Remove and replace bad ECM motor due to failed speed control. Motor will not spin faster than low fan.
2021 Carrier AC running in great condition. 20x25x4 air filter is new today. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Run test unit in cooling mode from thermostat. Delta t of 21F with supply temp of 51F. R410a refrigerant pressures are within spec. High 275psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.
Upon arrival inspected unit and found freezing temps inside. Inspected blower and blower motor will not change speed. Stuck in low speed. Blower motor will need replaced under parts warranty
Pulled and cleaned blower assembly with water and brush Brush cleaned and vacuumed secondary heat exchanger
Need two guys to pickup AC and pad to put a thicker base of gravel under. Will need to schedule a morning for this job.
Performed cooling maintenance on a Carrier AC system Washed aprilaire dehumidifier filter Humidifier shut down for summer Replaced 20x25x4 filter Left an additional filter per customer request at additional charge Blower is clean Drains are clear No concerns found on indoor portion of the system Tore down and washed outdoor unit **UNIT IS NOT PROPERLY GROUNDED** Builder needs to send their electrician out to correct this. Refrigerant charge is good Please pay balance for the extra filter. Thank you!
2022 Carrier AC is running in great condition. 20x25x4 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Run test unit in cooling mode from thermostat. Delta t of 21F with supply temp of 50F. Refrigerant pressures are within spec. High 275psi with 11F SC, low 115psi with 10F SH. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer. Regarding concerns of temperature differences between floor levels, recommend closing register ins basement, partially closing som on the first floor in areas that are not used often, make sure all registers on second floorare open, and leaving fan setting on thermostat in ON mode to continuously run the fan. All of these combined will help lower the temperature difference, but it will not eliminate it.
2016 Carrier AC running in good condition. 20x25x1 air filter in decent condition. Check again soon. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Run test unit in cooling mode. Delta t of 19F with supply temp of 49F. Refrigerant pressures are within spec. High 275psi with 14F SC, low 115psi with 8F SH. Outdoor coils flushed with water to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.
2023 Carrier AC running in great condition. 20x25x4 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Run test unit in cooling mode from thermostat. Delta t of 22F with supply temp of 50F. Refrigerant pressures are within spec. High 320psi with 11F SC, low 120psi with 10F SH. Outdoor coils are in clean condition. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer. Inspection on basement fan was inconclusive as fan started operating after being removed and inspected, then reinstalled.
Performed cooling maintenance on two Carrier AC systems Filters are new Blowers are clean Shut down humidifier Checked dehumidifier Drains are clear Refrigerant charge is correct for both systems Capacitors are in specification Wiring is secure and free of damage Disassembled both outdoor units and washed them with water Advised leaving the fan set to continuous operation for the downstairs system in the summer time to enable the whole-house dehumidifier to work more effectively.
2022 Carrier AC running in new condition. 20x25x4 air filter is new today. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Confirm proper blower speeds for cooling more on furnace blower settings. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 48F. Refrigerant pressures are within spec. High 245psi with 11F SC, low 115psi with 9F SH. Outdoor coils are in clean condition. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.
Perform heating PMI Clean flame sensor Flush drain trap Check blower and inducer amps verifying within spec Check delta T @ 55° Filter 24x25x4 due soon. No other concerns at this time only concerns discovered were drain trap and filter. Trap has been flushed and resolved