725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for lewis center, oh

Rated 4.9 out of 5 stars based on 18 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super nice tech

Jake was extremely nice, helpful and informative. A great asset to the company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, reliable service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Very friendly. Quick troubleshooting

Seth was fantastic! Quick to troubleshoot and let me know my system didn’t have any issues. Just paper caught in my blower!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

furnace was not running at all

I called on a Wed afternoon and booked the first available appointment - Fri a.m. Was called Thu morning and offered a cancellation slot later Thu morning, which I really appreciated (snow in the forecast Thu eve ... might have cooled off inside.) Received a call around 30 min before Seth arrived. Seth was right on time, and was very professional and pleasant. He was able to restart the furnace almost immediately, but he still took the time to check for any possible sources of the failure, and he patiently explained a lot to me about how the unit functioned. While he wasn't able to discover why the furnace quit working, I felt confident he'd done a thorough check. He also took the time to talk to me about my concerns about a whole-house humidifier that had been installed by the another service provider. I would not hesitate to work with Westin, or Seth, in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service Everytime

Seth and the team at Westin Air have been great to work with. Really appreciate their service and expertise.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Everything went great from the first phone call to the fixed air conditioner! I already put a good review up on Angie's List.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, quick response

Called first thing in the morning about my ac not working and someone was here that afternoon. Seth explained what was wrong in detail and fixed my issues.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Seth and Alex installed the water heater and accessories in a superb manner with great attention to detail. Seth was patient and lucid in explaining the issues with the A/C. Overall, an excellent experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Service

I had an extremely pleasant first-time experience with Westin Air. Laurie was super friendly and prompt with her phone calls and Seth was absolutely amazing. Will definitely be using you again for all of our HVAC needs and recommending you to family and friends!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service, Great Price

Called to inquire about Nest thermostat Install. Scheduled a same day appointment. Installer was friendly and helpful. I will definitely come to Westin Air for my HVAC needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Always pleasant and on time!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lewis center, oh

seth p.

seth p. Job Checkin

1st floor equipment will turn on in air conditioning mode but does not produce cooling System running refrigerant pressure test indicates a complete loss of all refrigerant Nitrogen pressure testing discovered a failed aluminum weld joints on the discharge line distribution manifold of the condenser coil Aluminum condenser coil needs replaced Parts warranty has been confirmed with 3 years remaining.


Graham M.

Graham M. Job Checkin

Upon arrival inspected furnace and with initial startup the inducer motor does not fully spin up as it should, when checking for voltage the motor was not receiving power and was not pulling amps. Control board was making a loud abnormal buzzing. Quote warranty control board, labor only no diag because I was just here for cooling maintenance.

Upon arrival inspected furnace and with initial startup the inducer motor does not fully spin up as it should, when checking for voltage the motor was not receiving power and was not pulling amps. Control board was making a loud abnormal buzzing. Quote warranty control board, labor only no diag because I was just here for cooling maintenance.

Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - Trane clean effects - filthy, wash with garden hose and reassemble Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Inspect outdoor unit - no concerns Hookup Daikin D-checker and verify no errors Delta T - 20° The Air handler and AC are in optimal running conditions.


Brandon P.

Brandon P. Job Checkin

Replace indoor coil under factory parts warranty. Pump down refrigerant into outdoor condenser unit. Remove flue vents and drain line for clearance. Installed new coil into existing casing. Installed new door with proper model and serial numbers for new coil. Replaced refrigerant filter drier. Open valves and test run operation. Charge in 4oz of new R410A to bring system to factory operating specs. Performed Gold cooling maintenance inspection after system was operating. 20x25x1 air filter is new today. Indoor coild brand new. Flushed drain. Test run in cooling mode from thermostat. Delta t of 20F with supply temp of 46F. Refrigerant pressures are within spec with a 10F SC. Water flushed outdoor coils to remove dirt and debris build up. Run capacitor is within spec. Outdoor fan motor and compressor are operating within specs.

Replace indoor coil under factory parts warranty. Pump down refrigerant into outdoor condenser unit. Remove flue vents and drain line for clearance. Installed new coil into existing casing. Installed new door with proper model and serial numbers for new coil. Replaced refrigerant filter drier. Open valves and test run operation. Charge in 4oz of new R410A to bring system to factory operating specs. Performed Gold cooling maintenance inspection after system was operating. 20x25x1 air filter is new today. Indoor coild brand new. Flushed drain. Test run in cooling mode from thermostat. Delta t of 20F with supply temp of 46F. Refrigerant pressures are within spec with a 10F SC. Water flushed outdoor coils to remove dirt and debris build up. Run capacitor is within spec. Outdoor fan motor and compressor are operating within specs.

Brandon P.

Brandon P. Job Checkin

Two system rooftop Lennox package HVAC cooling season annual maintenance, filter rotation, clean and check, minor maintenance repairs, coil flush and drain flush Inspect all cooling circuits, motors, and electronics All equipment is an acceptable condition but showing normal signs of regular wear and tear for 2016 equipment in a commercial application The smaller of two systems also has a loud condenser fan motor that does not appear to be affecting any operation at this time. Seth will prepare a estimate for condenser fan motor replacement asap

Two system rooftop Lennox package HVAC cooling season annual maintenance, filter rotation, clean and check, minor maintenance repairs, coil flush and drain flush 
Inspect all cooling circuits, motors, and electronics 

All equipment is an acceptable condition but showing normal signs of regular wear and tear for 2016 equipment in a commercial application 

The smaller of two systems also has a loud condenser fan motor that does not appear to be affecting any operation at this time. 

Seth will prepare a estimate for condenser fan motor replacement asap

Brandon P.

Brandon P. Job Checkin

370 volt 40+5uf capacitor replacement. Tested operation of compressor and fan motor with contactor.


Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - 16x25x1 filter Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 39.3+5.0 Check OD fan Amp - 0.62 Check compressor Amp - 8.10 Verify pressures and HP-SC/LP-SH 349-13/133-13 Delta T - 17° The Air handler and AC are in optimal running conditions.


Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - 20x25x4 new today Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 45+5 @ 43.8+4.99 Check OD fan Amp - 0.81 Check compressor Amp - 8.44 Verify pressures and HP-SC/LP-SH 323-16°/128-10° Delta T - 20° @ 1055 cfm 3 ton cond/evap coil The Air handler and AC are in optimal running conditions.


seth p.

seth p. Job Checkin

2019 carrier 13 seer 2.5 ton r410a cooling system was in desperate need of regular maintenance and cleaning and minor repair parts upon arrival today. The cased evaporator coil and all supply ducks in the mechanical room of the basement are sweating and condensating excessively due to restricted airflow on the indoor unit from a Honeywell 4-in filter installed backwards and sucked off the retainer screening, a heavily matted over and clogged up outdoor condenser coil, and a outdoor unit 370 volt power supply extremely below the specs. (40+5 @ 26+3.5) All contributing to very poor performance of the cooling system Install replacement air filter already on site and labeled the air cleaner with the proper air flow direction. Inspected the evaporator coil and confirmed 90 plus percent condensating. Confirm correct lower speed Water flush outdoor unit condenser coils and run test equipment and cooling mode. System refrigerant pressures are over specs at 15 subcooling however the true and


Graham M.

Graham M. Job Checkin

Upon arrival found outdoor unit not cycling compressor. Inspected capacitor and found 31mfd on compressor circuit. Replaced capacitor with 35+5 single cap because I didn’t have 35+5 on hand. Test ran system and unit properly cooling after replacing capacitor


Brandon P.

Brandon P. Job Checkin

2022 Carrier AC running in great condition. 16x25x1 air filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 51F. R410a refrigerant pressures are within spec. High 300psi with 11F SC, low 115psi with 9F SH. Outdoor coils are in clean condition. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.


seth p.

seth p. Job Checkin

2014 Bryant 4-ton cooling system is running in good condition after replacement of the 440 volt dual run power supply. Fan motor below specs at 6.2 compressor 45 UF @ 5.5 Water flush condenser coils Install new 45 + 7.5uf 440 volt power supply Run test cooling mode Supply air temperature is 64 and dropping at the garage laundry room entryway Homeowner will set thermostat temperatures and has already replaced the air filter


Jason D.

Jason D. Job Checkin

Install New Bryant Single-Stage Air Conditioner and Coil AC: GA4SAN53600N Serial #: 0525C59402 3 Ton - 13.4 SEER2 Coil: CVAVA3617XMA Serial #: 2325J71971 Installation: * Reconnect to existing high voltage electric * Transition to existing supply and return ductwork * Aprilaire 1210 (20x25) Media Air Cleaner * Start up and commission new system * Delaware County Permit Warranty: 10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


Brandon P.

Brandon P. Job Checkin

2020 Trane AC running in great condition. 20x25x4 air filter is new today. Whistling noise was due to air filter door not being closed all of the way and allowing some air to pass through. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 44F. Refrigerant pressures are within spec. High 240psi with 11F SC, low 110psi with 8F SH. Outdoor coils are in clean condition. Outdoor fan motor and compressor are operating within specs. System is operating properly, efficiently and ready for Summer.


Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found furnace setup moving high cfm doing low dehumidification. Adjust furnace settings to lower cfm for air conditioner bringing higher temperature drop, allowing unit to work faster and more efficiently dehumidifying. Thermostat occasionally goes into error state where it is blank and then says system wait once coming back. “System wait” is normal for any initial power up on the system. The thermostat should not be randomly going blank, adjusted wet switch to verify it stays dry unless drain errors are truly present. As well as adjust humidifier wiring to prevent any low voltage interference for thermostat. If problem persists unit may have a faulty thermostat or wet switch. Ss2 is the double locking tabs bucket style.