725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for lewis center, oh

Rated 4.9 out of 5 stars based on 18 customer reviews

Excellent Service by Gregg and his colleague

Greg and his colleague did awesome job balancing and providing recommendations. He also uncovered an issue that was kind a hidden.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Experience!

Chris was Amazing!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Super nice tech

Jake was extremely nice, helpful and informative. A great asset to the company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Friendly, reliable service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service. Very friendly. Quick troubleshooting

Seth was fantastic! Quick to troubleshoot and let me know my system didn’t have any issues. Just paper caught in my blower!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service and very knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

furnace was not running at all

I called on a Wed afternoon and booked the first available appointment - Fri a.m. Was called Thu morning and offered a cancellation slot later Thu morning, which I really appreciated (snow in the forecast Thu eve ... might have cooled off inside.) Received a call around 30 min before Seth arrived. Seth was right on time, and was very professional and pleasant. He was able to restart the furnace almost immediately, but he still took the time to check for any possible sources of the failure, and he patiently explained a lot to me about how the unit functioned. While he wasn't able to discover why the furnace quit working, I felt confident he'd done a thorough check. He also took the time to talk to me about my concerns about a whole-house humidifier that had been installed by the another service provider. I would not hesitate to work with Westin, or Seth, in the future.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service Everytime

Seth and the team at Westin Air have been great to work with. Really appreciate their service and expertise.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Everything went great from the first phone call to the fixed air conditioner! I already put a good review up on Angie's List.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, quick response

Called first thing in the morning about my ac not working and someone was here that afternoon. Seth explained what was wrong in detail and fixed my issues.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Seth and Alex installed the water heater and accessories in a superb manner with great attention to detail. Seth was patient and lucid in explaining the issues with the A/C. Overall, an excellent experience.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Service

I had an extremely pleasant first-time experience with Westin Air. Laurie was super friendly and prompt with her phone calls and Seth was absolutely amazing. Will definitely be using you again for all of our HVAC needs and recommending you to family and friends!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast Service, Great Price

Called to inquire about Nest thermostat Install. Scheduled a same day appointment. Installer was friendly and helpful. I will definitely come to Westin Air for my HVAC needs.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Always pleasant and on time!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for lewis center, oh

Graham M.

Graham M. Job Checkin

Original call was for duct popping Noise coming from soffit ceiling in finished basement. After listening to the noise discovered that it is nothing concerning and just a minor inconvenience.Noise from heat expansion and contraction. Informed homeowners of suggested maintenance and discovered a problem with the range wiring that needs to be addressed with the construction manager chris on a return visit. PmI will be completed upon return visit.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Carrier two stage 96% efficient gas furnace. Changed 20x25x1 Filter Humidifier pad is still in good shape Pulled and cleaned flame sensor Pulled and flushed condensate trap Tested furnace in high fire and low fire with the humidifier bypass damper open. Temperature rise within factory spec Gas pressures 3.2 and 1.7 Ran combustion test, heat exchanger pass.


Graham M.

Graham M. Job Checkin

Furnace maintenance inspection performed Inspect filter: 16x25x1 new today gold Inspect burners: Clean no concerns Ohm ignitor: 57.8 Clean flame sensor Inducer amps: 0.60 Blower Motor amps: 3.92 All wiring OK Humidifier: panel new today Temperature rise: 40⁰ Furnace is running in optimum condition.


Graham M.

Graham M. Job Checkin

Furnace maintenance inspection performed Inspect filter: 16x25x1 new today Inspect burners: Clean no concerns Ohm ignitor: 58 Clean flame sensor Inducer amps: 0.89 Blower Motor amps: 4.57 All wiring OK Humidifier: n/a Temperature rise: 54⁰ Furnace is running in optimum condition.


Brandon P.

Brandon P. Job Checkin

2022 Carrier high efficiency furnace running in new condition. 20x25x4 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Inducer and blower motors are operating properly and within specs. Humidifier pad in good condition, damper opened, run test during heating mode, and set to 35%. Run test furnace in heating mode from thermostat. Delta t of 56F with supply temp of 129F, Delta t spec of 40-70F. All systems are operating properly, efficiently and ready for Winter. Attached below are estimates for having a Wifi thernostat installed with gold member 10% discounts.


Brandon P.

Brandon P. Job Checkin

Talked to Shawn on the phone and he said he fixed it himself. Will be canceling the order.


seth p.

seth p. Job Checkin

Waterfurnace Envision NDV049 heating equipment tune up, maintenance, safety inspection, run testing. Upon arrival and initial inspection homeowner indicated a diagnostic LED flashing but stated all functions appear to be working normal. Currently the airflow LED and DHW LEDs are both flashing steady and neither will reset with any low voltage or high voltage power cycles. Complete all run testing, cleaning, and inspections before proceeding to tech support for additional information. Based on tech support Aarons guidance all functions & dip switches are set correctly and the premier control board appears to be actively failing by sending out false diagnostic signals to the LED display control board. Recommend replacing premier control board based on its current status and to prevent any complete breakdowns or no heat/cool conditions in the near future Also recommend less dense air filter to prevent high static pressures and excessive RPMs of the variable speed motor. MERV 8-11


seth p.

seth p. Job Checkin

2021 train 80+ gas heating system tune up, maintenance, cleaning, and filter rotation. Heavy Shop-Vac cleaning of the filter rack, install new replacement 16x25x1 plated disposable filter from truck stock, resurface flame sensor and inspect ignition system hot surface igniter, test run heat mode, test run thermostat and replace batteries provided by tenants 2 x AAs All equipment is clean and ready for winter


Brandon P.

Brandon P. Job Checkin

2019 Carrier furnace running in good condition. Installed new Carrier Air purifier cartridge that did not fix the ground ding issue within electronics of air purifier system. Contacted tech support while on site, but nobody was available at the time. Will need to call back once contact is made with tech support. Cleaned flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap. Test ran in heating mode from Google Nest thermostat. Delta t of 56F with supply temp of 130F, spec Delta t of 40-70F. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing in basement. Humidifier pad in good condition, damper opened, run test during heating mode. Blower housing, wheel, and compartment have a bit of dust buildup and is not a problem at this moment, but would recommend getting a blower cleaning done once ductwork cleaning is done as this will get a fair amount more of dust on to the blower system. Furnace is properly operating


Graham M.

Graham M. Job Checkin

Install temp stat, wire furnace for temporary operation and finish drain. Set gas pressures. Fire furnace off Set stat at 70


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2004 Trane furnace. System is operational but in poor condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap. Humidifier pad in good condition, damper opened, run test during heating mode, set to 35%. 3" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Ran test in heating mode from Google Nest thermostat. Delta t of 41F with supply temp of 116F, delta t spec of 30-60F. Blower motor and blower capacitor are operating within spec. Inducer/exhaust motor is operating within Amp draw specifications, but has signs of water damage with rust on outer casing and parts internally on the motor. The exhaust motor/housing is also making a noise that sounds like bearing noise meaning the motor could fail soon. With the age and condition of the unit, in the event of a break down and a major part needing to be replaced, recommend replacing entire unit as it could become a money pit.


Graham M.

Graham M. Job Checkin

Furnace maintenance inspection performed Inspect filter: 16x25x1 Inspect burners: Clean Ohm ignitor: 82ohms Clean flame sensor Inducer amps: 0.43 Blower Motor amps: 2.58 All wiring OK Humidifier: n/a Temperature rise: 55⁰ Furnace is running in optimum condition.


Brandon P.

Brandon P. Job Checkin

2017 Lennox high efficiency furnace running in great condition. 16x25x1 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Inducer and blower motors operating within spec. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing in furnace area. Run test furnace in heating mode from thermostat. Delta t of 59F with supply temp of 130F, spec Delta t of 40-70F. Furnace is operating properly and ready for Winter.


Graham M.

Graham M. Job Checkin

Furnace maintenance inspection performed Inspect filter: 16x25x1 clean Inspect burners: no concerns Ohm ignitor: 53.2 Clean flame sensor Inducer amps: 0.49 Blower Motor amps: 3.0 All wiring OK Humidifier: n/a Temperature rise: 60⁰ Furnace is running in optimum condition. Sharon would like her air conditioner raised and leveled come next spring visit


Nate G.

Nate G. Job Checkin

Adjusted open limit on back of the house zone 2 damper to be choked down. Master register went from 250fpm to 430fpm.