Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!
Overall Experience
Quality
Price
Convenience
My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)
Overall Experience
Quality
Price
Convenience
Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!
Overall Experience
Quality
Price
Convenience
Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.
Overall Experience
Quality
Price
Convenience
Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.
Overall Experience
Quality
Price
Convenience
We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!
Overall Experience
Quality
Price
Convenience
When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.
Overall Experience
Quality
Price
Convenience
Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.
Overall Experience
Quality
Price
Convenience
Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!
Overall Experience
Quality
Price
Convenience
Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.
Overall Experience
Quality
Price
Convenience
Preventative maintenence inspection on Trane high efficiency furnace running in good condition. Clean Effects pre filter cleaning. Clean flame sensor and check ignitor ohms. Visual inspection of burners. Flush condensation trap and drain lines Humidifier pad is in dirty condition and could cause a leak. Edmsaid they will get a new humidifier pad themselves. Test ran furnace in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Humidifier tested during heating mode test. No issues found or suspected with equipment at this time. System is operating properly, efficiently and ready for Winter.
Preventative maintenence inspection on Trane standard efficiency gas furnace running in good condition. 16x25x1 air filter in decent condition. Check again in 1-2 weeks due to remodel work. Clean flame sensor and check ignitor ohms. Visual inspection of burners. Test ran in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter. Will need to be rescheduled for humidifier install.
Gas heating preventative maintenance performed Check filter - 16x25x1 clean Clean flame sensor Inspect burners - clean Ohm test igniter: 50.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.3 Check amp draw on inducer motor:0.67 Check delta T - 48 Furnace is in optimal running conditions
Preventative maintenence inspection on Lennox standard efficiency furnace running in good condition. 16x25x1 air filter in decent condition. Check again in 1-2 months. Clean flame sensor and check ignitor. Visual inspection of burners. Helen mentioned a noise when starting up. Duringntest run, nothing unusual was heard. Noise that is being heard is the exhaust motor and is operating normally. Test ran in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Galvanized B-vent is in good condition with no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Upon arrival inspected system and found blower motor not operational as stated from homeowner. Inspected blower and unit getting power but not coming on. ECM motor is bad and needs replaced. GeoCool/mrcool geothermal support was unavailable when I called.
Preventative maintenence inspection on Tempstar high efficiency furnace running in great condition. 16x25x4 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.
Upon arrival, both main breaker panel and internal disconnect breaker were tripped. Turned thermostat off and attempted to reset power. Both breakers go back on with no trips and ther is 208V to the system. First tried to test run fan only, and found that the blower will not kick on. Blower relay clicks and is supplying motor with proper voltage, but no operation. Blower motor has failed and will need replaced. Suspect that blower motor shorted internally leading to breakers tripping and has completely internally failed leading to no breakers tripping even when power is supplied. Quote for blower motor replacement will be made and sent over Friday, January 2nd, sometime in the morning.
Upon arrival inspected system and found unit in E09 cycle. Each time unit started it would stop running due to E09. Inspected all limits and switches and found no errors on switches, aside from condensate switch tripped while running. Hookup manometer to condensate and monitor never changing from 0.8. Unit will not fault after inspecting pressure switch. Believe water was in switch faulting pressure switch or switch itself may be on the way out becoming faulty. Unit running fine at this time post inspection.
2013 ICP 80% single stage furnace 16x25x1 filter needs replaced Cleaned flame sensor Adjusted gas pressure to 3.2" WC Inducer motor bearings beginning to fail Recommend replacing inducer motor before it completely stops, leaving the furnace inoperable Vent piping in good shape Blower wheel is a little dirty, but not causing operational issues with heat Burners are in good shape No gas leaks detected Furnace is operating within factory specs at this time
Preventative maintenence inspection on Tempstar high efficiency furnace running in great condition. 20x25x4 air filter in decent condition. Check again in 1-2 months. Humidifier pad in new condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Reprogrammed and confirmed proper wiring of thernostat and humidifier for increased operation allowance. Previously, humidifier would only run when heating is running. Programmed stat and confirmed proper wiring to allow humidifier to run whenever a call for humidity is present. Humidifier will now operate whenever it is needed. All systems for heating and humidification are operating properly. Claire also asked about owners manual literature for thermostat as there was none l
Gas heating preventative maintenance performed Check filter - Trane clean effects ok Clean flame sensor Inspect burners - pull and wire brush Ohm test igniter: 54.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.5 Check amp draw on inducer motor:0.24 Check delta T - 54° Furnace is in optimal running conditions
Preventative maintenence inspection on Trane S9V2 high efficiency furnace running in great condition. Two 20x25x4 air filters are in good condition. Check again in 1-2 months. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier pad in good condition, damper is already open. Test operation of humidifier. No issues. Tes run gas heating. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter Mike mentioned that the humidifier seems to run constantly or for extended periods of time. Due to both the lower temperatures and flonger furnace operation times causing lower humidity, the Humidifier will undoubtedly run longer to compensate. Indoor humidity during inspection was 43%. If the humidifier is struggling to keep up at approximately 30-35% then ther may
SOLD: 11/29/2025 10:36:37 PM - Option 1 Install New Bryant HVAC System Bryant Preferred 96 2-Stage Gas Furnace Model #: 926TC48060V17A-A Serial #: 4125A44200 60,000 BTU's - 96% AFUE Bryant Single-Stage Air Conditioner Model #: GA5SAN53000WAACC Serial #: 4425C19987 2.5 Ton - 15 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA3017XMAEAAA Serial #: 2525J83226 Installation: * Additional Services - New PVC Furnace vents. Level 2 * Install 50 Gal Electric Bradford White Hot Water Heater * Reroute 8" return to drop, move 7" run to plenum * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be perf