Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!
Overall Experience
Quality
Price
Convenience
My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)
Overall Experience
Quality
Price
Convenience
Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!
Overall Experience
Quality
Price
Convenience
Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.
Overall Experience
Quality
Price
Convenience
Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.
Overall Experience
Quality
Price
Convenience
We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!
Overall Experience
Quality
Price
Convenience
When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.
Overall Experience
Quality
Price
Convenience
Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.
Overall Experience
Quality
Price
Convenience
Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!
Overall Experience
Quality
Price
Convenience
Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.
Overall Experience
Quality
Price
Convenience
Preventative maintenence inspection on Trane XT80 furnace running in great condition. Trane Clean Effects filter cleaning. Clean flame sensor and check ignitor. Visual inspection of burners. Test ran in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter.
Preventative maintenence inspection on Carrier high efficiency furnace running in great condition. 20x25x4 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. Test ran operation of geothermal heating aswell. Temperature rise is within specs. Did not check refrigerant as there is no issues suspected. No fault codes stored in system. All systems are operating properly, efficiently and ready for Winter.
Preventative maintenence inspection on 2025 Daikin gas furnace. 16x20x4 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Test run in heating mode from thermostat. Temperature rise is within specs. Blower and inducer motors tested good. 2-3in pvc flue in good condition and no sign of leaks. System is operating properly, efficiently and ready for Winter. Leveled outdoor ac to prevent damage and nonunitorm appearance.
Preventative maintenence inspection on Trane XR80 furnace. 20x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Brenda mentioned a vibration noise when first turning on. Upon initial test run, bount that two screws on the exhaust motor were loose and allowing the motor to vibrate. Tightened screws and test ran system in heating mode. No more noise heard. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Furnace is operating properly, efficiently and ready for Winter.
Goodman 80% efficient 40kbtu natural gas furnace Hot surface igniter failed Got approval to replace igniter Furnace is in poor overall shape and over 20yrs old Replacement will be required in the near future
Inspected heat exchanger with camera. Found multiple cracks and rust holes. Evaporator coil 50% plugged with dirt System is 20 years old Do not recommend repairs Cathy gave a quick replacement number Customer approved Need to send over a formal replacement proposal ASAP and replace equipment at earliest possible date
2017 Trane XT95 Fuenace. 16x25x1 air filter on schedule with Jack. Cleaned flame sensor. Flush out drain trap. Test run operation of heating from thermostat. Temperature rise of 53F with supply temp of 125F. Temperature rise specification of 30-60F. Blower motor and inducer motor running within spec. 2" Pvc flue in good condition with no sign of leaks. Jack brought up the concern of a metal on metal grinding noise. No noise was heard while on site for preventative maintenence inspection. If noise is heard again, it is recommended to try and take a video of the noise, and try to locate the place of origin to assist with diagnostics. System is currently operating with no suspected issues based on today's inspection and testing.
Customer states had ductwork cleaned and a UV light installed Odor came after that Ran furnace and turned UV on Do not smell any odd odors from the ducts in question As a precaution shut off UV light
Preventative maintenence inspection on Trane high efficiency furnace. 20x25x4 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Gas furnace is operating properly. Tested operation of geothermal heating. Ground loop pressure is within spec. Geothermal heating temperature rise is within specs. Did not check refrigerant as there is no issues suspected at this time. System is operating properly, efficiently and ready for Winter.
Smaller heat pump unit for the clubhouse room Diagnosed failed thermostat Replaced thermostat Verified correct operation of the equipment (shuts off and on with the thermostat at appropriate times)
2012 Lennox air handler with straight AC Tenant explained the system is working properly now She said she reported this to Tabitha Verified correct operation while on site by cycling heat at the thermostat Incorrect filter size is being used currently Filter needs to be a 16x20x1 or a 16x25x1 Current filter is a 14x25x1. Incorrect width allows dirt to get around the filter and plug the coil and blower. Also noted condensate drain is installed incorrectly Drain requires a P-trap If the filter gets wet during air conditioning operation, installing a P-trap will remedy the situation
Gas heating preventative maintenance performed Check filter - 20x25x4 new today gold Clean flame sensor Ohm test igniter: 49.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: N/A Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 6.24 Check amp draw on inducer motor:1.21 Check delta T - 50° Furnace is in optimal running conditions Gas heating preventative maintenance performed Check filter - 20x25x4 new today gold Clean flame sensor Ohm test igniter: 58.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 4.38 Check amp draw on inducer motor:0.98 Check delta T - 55° Furnace is in optimal running conditions
Preventative maintenence inspection on Trane geothermal and Daikin Heat Pump systems. Both systems are operating properly and efficiently. Both air filters are in good condition. There is already a 20x25x4 on site for Trane geothermal unit. Nancy asked that I leave a clean AA210 filter for the daikin system so they can be changed in the spring. Tested electric strip heating on both units to verify proper electric usage. All heating strips are operating properly. Blower motors are operating properly. Test ran heat pump heating on both units with no issues found or suspected. Recently installed NP flow center is full and operating properly. All systems tested good. Units are operating properly, efficiently and ready for Winter.
Upon arrival inspected system for any bacteria buildup, found no major concerns with main system. Only concerns are underlying with the ductwork. The existing ductwork is very filthy internally and possibly a heavy cause of the allergy attacks. Recommend fresh air corp to come perform full ductwork cleaning. After bacteria inspection was performed, perform heating inspection verifying ready for the winter season. Gas heating preventative maintenance performed Check filter - 20x20x1 new today Clean flame sensor Ohm test igniter: 54.7 ohms Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.64 Check amp draw on inducer motor:0.78 Check delta T - 53° Furnace is in optimal running conditions
2004 Trane furnace. Upon arrival, system is in off mode. Test run operation twice with no obvious issues. Inspection of unit and further description of the behavior of the unit from Brandon, it is suspected thatcthe flame sensor is dirty, and causing issues. Removed and inspected flame sensor and found it mostly soot covered. Pulled burners and inspected those aswell. Cleaned flame sensor and brushed off burners. No rust is present on flame sensor or burners. Reinstalled flame sensor and burners, and test ran operation twice more with no issues. System is operational at this time.