Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!
My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.
Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!
Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)
Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!
Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.
Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.
We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!
When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.
Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.
Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!
Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.
Perform cooling preventative maintenance Inspection air filter - 16x25x4 ok Check delta T - 21° Check refrigerant pressures 12° subcool Check run capacitor - 40+5 @ 39.9+5.03 Coil clean doesn’t need washed today.
Performed cooling maintenance Store manager said the north and south units are needing replaced. Middle unit is 3 years old and in good shape South unit is completely dead: parts have been robbed off of it leaving it to zero functionality. North unit heating section is not functional and has a bad heat exchanger. Repairs to get this unit heating again will be North of $6,000 North unit cooling does work but only one of the two compressors functions currently. In order to get the larger of the two compressors going again, it requires a new contactor. Manager requests quote for replacing the south unit.
2014 Trane XC 95M Upon arrival today the dining room / kitchen system was below the set point calling for heat with only the inducer motor running. Four pages of diagnostic service codes between April 13th and today. All service codes indicate a intermittently failing integrated furnace control Install replacement IFC control board upgrade kit including inducer variable speed module Test run system in heating mode and cooling mode from the XL950 communicating control with no errors or faults Replace all basement air filters and shut down both humidifiers for summer Cooling maintenance will be performed next week *Homeowners will complete invoicing with online pay
Performed cooling PMI inspected air filter - due soon from 8/17/2024 Turned on cooling shut down humidifier Cooling droop - 22° Capacitor outdoor - 35+5 @ 34.9+4.9 Coil didn’t need washed coil is clean Pressures looked good for outdoor temperature being 48° Everything is in spec and unit should be ready for summer
Purchase 2025 geothermal annual maintenance plan Perform cooling inspection while on site today Waterfurnace Envision packaged geothermal equipment is in fair to poor condition but does appear to be holding the refrigerant pressures since the last visit. Equipment is confirmed to have refrigerant leaks in unknown possibly multiple locations in the past and has been treated with leak stop and dye. The air coil drain Pan has also been resealed multiple times in attempts to stop the water leak due to cracked plastic For the sake of refrigerant pressure and cooling mode testing the zone system controls have been disabled and isolated for test mode. Run test equipment in multi-stage heat pump cooling mode and confirm 42° supply temperature Ground loop system is running at 30 psi and 46° in preseason cooling test mode Water furnace 2-in disposable air filter is in acceptable condition at this time. Homeowners have been notified no more filters are on site in the basement. Shut down bo
Install New Bryant HVAC System Furnace: 800SB36070M17 Serial #: 4824A14810 70,000 BTU's - 80% AFUE AC: 134SAN03000N Serial #: 1325C40225 2.5 Ton - 15 SEER2 Coil: CVAVA3017XMA Serial #: 1125J17177 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Connect to Existing Thermostat * Aprilaire 1210 Media Air Cleaner Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Install New Bryant Air Conditioner and Coil AC: GA5SAN41800W Serial #: 3223X40019 1.5 Ton 14.3 SEER2 – 11.7 EER2 Coil: CVPVA1917XMC Serial #: 3224J47809 Installation: * Reconnect to existing high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Cut off Brackets & place AC on New Pad Warranty: 10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
Two system both split systems hybrid Carrier gas heat with water furnace geothermal Replace air filters on both systems, extra air filters for the back system and homeowner will order new filters for the basement. Turned off humidifier for summer time, run test multi-stage cooling on both systems, basement non-pressurized glycol system running excellent, back addition system also running in excellent condition however the pressurized ground loop needed recharged from 0 PSI to maximum house water pressure of 55 while running in cooling mode Disassemble basement condensate drain pump for sediment cleaning, freshwater flush back system drain pump and both air coil drain traps Scan and clear geothermal diagnostics memory Thermostats were inspected but never adjusted from the homeowners current settings All equipment is clean safe and ready for summer
Install 2 New Daikin FIT HVAC Systems Horizontal Applications Furnaces: DM96VC0603BNAC Serial #'s 630 S Pearl St: 2311018195 628 S Pearl St: 2312211121 AC's: DC6VSS2410AA Serial #'s 630 S Pearl St: 2407015063 628 S Pearl St: 2409166686 Coil's: CAPEA3022C3AA Serial #'s 630 S Pearl St: 2411265169 628 S Pearl St: 2501519935 Daikin One+ Thermostats: DTST-TOU-A Serial #'s 630 S Pearl St: EA2304004660 628 S Pearl St: EA2303004790 Installation: * Reconnect to existing gas lines and electric * Transition to existing supplies and return ductwork * Start up and commission new systems * 2 - Aprilaire 1210 (20x25) Media Air Cleaner * Ductwork Modifications to Change Furnaces & Coils Orientation to Horizontal Warranty: 12 Year Daikin manufacturers Parts Warranties (Annual maintenance must be performed) 2 Year Westin Air Labor Warranties (Annual maintenance must be performed) Daikin manufacturers Lifetime Heat Exchanger Warranties (Annual maintenance must be performed)
Install 2 Bradford White Hot Water Heaters Model #: RG240S6N-264 Serial #'s: AJ53979640 AJ53979660 40 Gallon - Natural Gas 6 Year Manufacturers Parts Warranty
OEM Trane blower motor replacement ECM MOT18721 SM1397 Devonhurst Confirmed parts warranty through 2030 After a replacement part with clean pleated 1-in filter the system is short cycling on primary limit Reduce gas pressure one full turn increase ECM speed from Tap 5 to Ap 6 Warranty parts are in Seth's truck Control board replacement is not required and parts order will be canceled
Furnace blower motor is non-functional. heating is short cycling on primary thermal limit. Condenser turns on when hot wired to yellow. No operation on any speed taps continuous on tap 1, cooling tap 7 heating tap 5 Confirmed system part warranty until 2030 No signs of water damage at this time Blower motor is in stock Control board is 4 to 5 days special order from Arizona Warranty parts replacement estimates sent to homeowner office staff will reschedule ASAP
Install AprilAire 1210 high efficiency media air filter and rack to lower static pressure and improve air flow. Return air static pressure has decreased from 0.4inwc to 0.24inwc. Verified heating and cooling fan speed for proper airflow. Replace thermostat with Honeywell T4 Pro a d test run in heating mode.
Upon arrival inspected furnace and found unit unable to sense flame. Unit fired up as it should but shut down almost instantly due to flame sense error. Disassembled furnace and cleaned flame sensor and white dusty burners to verify issue source. After cleaning furnace the unit stayed running and didn’t have any other issues. Air filter in good condition probably 2 weeks old.
Waterfurance 7 Series geothermal unit is running in perfect condition. Refrigerant and ground loop pressures and temperatures are within spec. Cooling operation is within spec. Tested operations and took measurements through Aurora Aid Tool. Air filter is in decent condition. Recommend changing in approximately 1-2 months. Normal codes for operations are present such as HW limit and system reset. Code E55 for Out of Envelope is tripped when outdoor temperatures are low enough that the self learning part of the system knows to automatically start at a higher stage than normal to prevent unsatisfactory operation. Code E55 does not have anything to do with the incoming high voltage that was discussed while maintenance was being my performed. No issues were found and system is operating properly.