725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for columbus, oh

Rated 4.8 out of 5 stars based on 43 customer reviews

Exceptional Service

Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest and fair

My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

service call

seemed costly

  • Overall Experience
  • Quality
  • Price
  • Convenience

The BEST service in town!

Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Job as always

Thank you for all your help Westin Air!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Straight shooter

Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always a great experience!

Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always Five Stars

Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt, thorough and courteous installation. They were great!

Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very responsive in fixing issues

When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Willing to work with you

Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service all the time

Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for columbus, oh

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane furnace. 20x25x4 air filter in good condition. Clean flame sensor and check ignitor. Visual inspection of burners. Humidifier pad in good condition. Damper is open. Test run furnace in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 1993 Janitrol furnace running in good condition despite its age. Replaced air filter with new one supplied by Kathy. Cleaned flame sensor and checked ignitor. Visual inspection of burners. Tested blower motor capacitor. Test ran system in heating mode from thermostat. Delta t of 54F with supply temp of 121F, spec 40-70F. Blower motor and inducer motor running within spec. Galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Replaced batteries in thermostat and basment CO detector. System is operating properly, efficiently, safely and ready for Winter.

Preventative maintenence inspection on 1993 Janitrol furnace running in good condition despite its age. Replaced air filter with new one supplied by Kathy. Cleaned flame sensor and checked ignitor. Visual inspection of burners. Tested blower motor capacitor. Test ran system in heating mode from thermostat. Delta t of 54F with supply temp of 121F, spec 40-70F. Blower motor and inducer motor running within spec. Galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Replaced batteries in thermostat and basment CO detector. System is operating properly, efficiently, safely and ready for Winter. Preventative maintenence inspection on 1993 Janitrol furnace running in good condition despite its age. Replaced air filter with new one supplied by Kathy. Cleaned flame sensor and checked ignitor. Visual inspection of burners. Tested blower motor capacitor. Test ran system in heating mode from thermostat. Delta t of 54F with supply temp of 121F, spec 40-70F. Blower motor and inducer motor running within spec. Galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. Replaced batteries in thermostat and basment CO detector. System is operating properly, efficiently, safely and ready for Winter.

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on 2024 Daikin modulating high efficiency gas furnace. Aprilaire 210 airmfilter in decent condition, check again in 1-2 months. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Gas furnace is operating properly, and within manufacturers specifications. Tested operation of humidifier during heating test, and opened damper. Furnace is operating properly, efficiently and ready for Winter.


Brandon P.

Brandon P. Job Checkin

Upon arrival thermostat was reading no power from hvac equipment. Inspection of furnace showed that it was not on. Checked to make sure breaker and service disconnect were on. Took off bottom door and inspected for any loose wiring. Manually pressed in the door switch and system came on. Door was not on properly and not depressing the door switch. Put door back on and tested operation. Furnace came on in heating as it should. Gas pressure sounded high. Checked gas pressure and it was at 3.8inwc. Set to 3.2inwc to ensure system does not overheat. After installing the top door back on, the system ran for approximately 20-30 seconds before being snuffed out. Inspected outdoor termination for concentric vent and found thatca grill was blocking the vent and causing recirculation. Moved grill and test ran system again. No other issues found or suspected during test runs. Pvc flue vents are installed properly, and pvc drain line is installed correctly to the adjacent drain setup.

Upon arrival thermostat was reading no power from hvac equipment. Inspection of furnace showed that it was not on. Checked to make sure breaker and service disconnect were on. Took off bottom door and inspected for any loose wiring. Manually pressed in the door switch and system came on. Door was not on properly and not depressing the door switch. Put door back on and tested operation. Furnace came on in heating as it should. Gas pressure sounded high. Checked gas pressure and it was at 3.8inwc. Set to 3.2inwc to ensure system does not overheat. After installing the top door back on, the system ran for approximately 20-30 seconds before being snuffed out. Inspected outdoor termination for concentric vent and found thatca grill was blocking the vent and causing recirculation. Moved grill and test ran system again. No other issues found or suspected during test runs. Pvc flue vents are installed properly, and pvc drain line is installed correctly to the adjacent drain setup. Upon arrival thermostat was reading no power from hvac equipment. Inspection of furnace showed that it was not on. Checked to make sure breaker and service disconnect were on. Took off bottom door and inspected for any loose wiring. Manually pressed in the door switch and system came on. Door was not on properly and not depressing the door switch. Put door back on and tested operation. Furnace came on in heating as it should. Gas pressure sounded high. Checked gas pressure and it was at 3.8inwc. Set to 3.2inwc to ensure system does not overheat. After installing the top door back on, the system ran for approximately 20-30 seconds before being snuffed out. Inspected outdoor termination for concentric vent and found thatca grill was blocking the vent and causing recirculation. Moved grill and test ran system again. No other issues found or suspected during test runs. Pvc flue vents are installed properly, and pvc drain line is installed correctly to the adjacent drain setup.

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on three furnaces. All air filters are in clean condition. Cleaned flame sensors and checked ignitors. Visual inspection of burners. Flush condensation trap and drain lines on high efficiency furnace. Test rancall units in heating mode. All systems are operating properly within temperature rise specifications. All blower motors and inducer motors are operating properly. Vent pipes are all in good condition and no sign of leaks. 0PPM CO detected during testing. Systems are operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Free second opinion on condemned Lennox furnace from worthington air Unit not operable. Replacement recommended

Free second opinion on condemned Lennox furnace from worthington air
Unit not operable. Replacement recommended Free second opinion on condemned Lennox furnace from worthington air
Unit not operable. Replacement recommended

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed basement Check filter - 20x25x4 new today Clean flame sensor Ohm test igniter: 58.3 Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 3.4 Check amp draw on inducer motor:0.9 Check delta T - 58° Furnace is in optimal running conditions Electric air handler preventative maintenance performed attic Check filter - 16x20x1 new today Inspect wiring for loose connections and/or hot spots - none found Set thermostat for heat Check amp draw on blower motor: 2.0 Check delta T - 45° with electric Air handler is in optimal running conditions


Graham M.

Graham M. Job Checkin

Unit was replaced recently by us. Installers accidentally left common wire for humidifier on W1 forcing furnace to run constantly. Repaired mistake and test ran system. No further concerns, gas pressure properly and AC blower speed set properly.

Unit was replaced recently by us. Installers accidentally left common wire for humidifier on W1 forcing furnace to run constantly. Repaired mistake and test ran system. No further concerns, gas pressure properly and AC blower speed set properly.

Graham M.

Graham M. Job Checkin

Upon arrival inspected unit and found furnace was overheating on E09, no specific causes for overheating aside from the gas pressure at 2.0 on low 3.7 high set pressures down to 1.5 low and 3.2 low and adjust blower speeds on system to assist with allowing heat to escape the burner compartment. Previous invoice disappeared, upon last visit found blower limit was unplugged at the housing inside unit from different company replacing the motor. Test ran system and heat was operational after adjustments were made but system had been still overheating.


Jason D.

Jason D. Job Checkin

ductwork assessment, adjustment or an air balance


Graham M.

Graham M. Job Checkin

Furnace issues from previous visit likely caused from intake air allowing hot humid air into the furnace while it is moving cool air through the house and that temperature mixture is likely what caused the super bad rust issue and inducer to lock up. Advised homeowner possible remediation would be removing fresh air intake and instead pulling intake from basement to go around the condensation source. Homeowner is possibly interested in revisiting remediation plans come spring time. Could install stainless steel burners or could just change over to 1 pipe.


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2011 two stage high efficiency tempstar natural gas furnace Replaced 16x25x4 filter Blower capacitor tested 9.7mfd, rated 10mfd Pulled and cleaned flame sensor Pulled and flushed condensate trap (had lots of gunk come out) Blower is in OK condition High fire gas pressure set to 3.0"wc, temp rise 65⁰ Low fire gas pressure set to 1.7" temp rise 52⁰ Ran combustion test, readings are within nominal ranges for both fire rates Tested supply air for carbon monoxide during operation. 0ppm registered Furnace is safe to operate and running within factory specifications at this time.

Performed heating maintenance on a 2011 two stage high efficiency tempstar natural gas furnace
Replaced 16x25x4 filter
Blower capacitor tested 9.7mfd, rated 10mfd
Pulled and cleaned flame sensor
Pulled and flushed condensate trap (had lots of gunk come out)
Blower is in OK condition
High fire gas pressure set to 3.0"wc, temp rise 65⁰
Low fire gas pressure set to 1.7" temp rise 52⁰
Ran combustion test, readings are within nominal ranges for both fire rates
Tested supply air for carbon monoxide during operation. 0ppm registered
Furnace is safe to operate and running within factory specifications at this time.

Jason D.

Jason D. Job Checkin

SOLD: 09/30/2025 8:24:27 AM - Option 2 Install new Bryant HVAC system Equipment: Furnace- 926TC48080V17A-A Serial# 3925A61061 AC- GA5SAN54200WABAG Serial# 3425G12392 Coil- CVAVA4217XMAEAAA Serial# 1825J21308 Installation: *Air Filtration: Aprilaire 1210 (20x25) Media Air Cleaner *Aprilaire Model 620M Humidifier *Duct Work - Replace Return Air Drop *Move AC around the corner *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)


SOLD: 09/30/2025 8:24:27 AM - Option 2

Install new Bryant HVAC system

Equipment:
Furnace- 926TC48080V17A-A
Serial# 3925A61061
AC- GA5SAN54200WABAG
Serial# 3425G12392
Coil- CVAVA4217XMAEAAA
Serial# 1825J21308

Installation:
*Air Filtration: Aprilaire 1210 (20x25) Media Air Cleaner
*Aprilaire Model 620M Humidifier
*Duct Work - Replace Return Air Drop
*Move AC around the corner
*Reconnect to existing gas line and high voltage electric
*Transition to existing supply and return ductwork
*Start up and commission the new system

Warranty:
10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed) 
SOLD: 09/30/2025 8:24:27 AM - Option 2

Install new Bryant HVAC system

Equipment:
Furnace- 926TC48080V17A-A
Serial# 3925A61061
AC- GA5SAN54200WABAG
Serial# 3425G12392
Coil- CVAVA4217XMAEAAA
Serial# 1825J21308

Installation:
*Air Filtration: Aprilaire 1210 (20x25) Media Air Cleaner
*Aprilaire Model 620M Humidifier
*Duct Work - Replace Return Air Drop
*Move AC around the corner
*Reconnect to existing gas line and high voltage electric
*Transition to existing supply and return ductwork
*Start up and commission the new system

Warranty:
10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed)

Jason D.

Jason D. Job Checkin

Install new gas Bryant HVAC system in attic and utilize existing ductwork. Equipment: Furnace- 800SB42090M17 Legacy, 80% AFUE, Single Stage, 4-Way Multipoise, MCT ECM, Gas Furnace, 90K, 17" width Serial# 3625A18065 AC- GA5SAN53600W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3 Ton GA5SAN53600WABAA Serial# 1125X61476 Coil- CVAVA3617XMAEAAA Serial# 2225J50026 T4 Pro Honeywell thermostat Installation: *Reconnect to existing high voltage electric *Connect to gas line supplied by D+L Plumbing *Transition to existing supply and return ductwork *Reuse existing air filter grills *Terminate furnace B-Vent through shingle roof with cap, collar and flashing *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)


Install new gas Bryant HVAC system in attic and utilize existing ductwork.

Equipment:
Furnace- 800SB42090M17 Legacy, 80% AFUE, Single Stage, 4-Way Multipoise, MCT ECM, Gas Furnace, 90K, 17" width
Serial# 3625A18065
AC- GA5SAN53600W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3 Ton
GA5SAN53600WABAA
Serial# 1125X61476
Coil- CVAVA3617XMAEAAA
Serial# 2225J50026
T4 Pro Honeywell thermostat

Installation:
*Reconnect to existing high voltage electric
*Connect to gas line supplied by D+L Plumbing
*Transition to existing supply and return ductwork
*Reuse existing air filter grills
*Terminate furnace B-Vent through shingle roof with cap, collar and flashing
*Start up and commission the new system

Warranty:
10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed)



Install new gas Bryant HVAC system in attic and utilize existing ductwork.

Equipment:
Furnace- 800SB42090M17 Legacy, 80% AFUE, Single Stage, 4-Way Multipoise, MCT ECM, Gas Furnace, 90K, 17" width
Serial# 3625A18065
AC- GA5SAN53600W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3 Ton
GA5SAN53600WABAA
Serial# 1125X61476
Coil- CVAVA3617XMAEAAA
Serial# 2225J50026
T4 Pro Honeywell thermostat

Installation:
*Reconnect to existing high voltage electric
*Connect to gas line supplied by D+L Plumbing
*Transition to existing supply and return ductwork
*Reuse existing air filter grills
*Terminate furnace B-Vent through shingle roof with cap, collar and flashing
*Start up and commission the new system

Warranty:
10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed)

Nate G.

Nate G. Job Checkin

9 systems total 8 split systems (air handlers with strip heat and heat pumps, except system 3 has straight AC condenser) 1 mini split ductless 12 filters replaced 2 times a year (7) 16x25x1 (2) 20x25x1 (2) 22x26x1 (1) 17x21x1 2 belts (1) AX48 (1) AX47 Will need at least 250' of garden hose and a hydrant key 5 of the air handlers are above drop ceilings on the first floor 8' ladder will be needed

9 systems total
8 split systems (air handlers with strip heat and heat pumps, except system 3 has straight AC condenser)
1 mini split ductless
12 filters replaced 2 times a year 
(7) 16x25x1
(2) 20x25x1
(2) 22x26x1
(1) 17x21x1
2 belts 
(1) AX48
(1) AX47

Will need at least 250' of garden hose and a hydrant key
5 of the air handlers are above drop ceilings on the first floor
8' ladder will be needed 9 systems total
8 split systems (air handlers with strip heat and heat pumps, except system 3 has straight AC condenser)
1 mini split ductless
12 filters replaced 2 times a year 
(7) 16x25x1
(2) 20x25x1
(2) 22x26x1
(1) 17x21x1
2 belts 
(1) AX48
(1) AX47

Will need at least 250' of garden hose and a hydrant key
5 of the air handlers are above drop ceilings on the first floor
8' ladder will be needed