Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!
My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.
Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!
Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)
Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!
Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.
Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.
We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!
When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.
Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.
Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!
Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.
Install new Daikin FIT HVAC system Furnace: DD80TC0603BXA 80% AFUE Two-Stage Variable-Speed Downflow Gas Furnace Serial# 2504226567 AC: DC6VSS2410A 16.2 SEER2 FIT Variable-Speed Inverter AC with R-32 Serial# 2503092497 Coil: CAPEA2418B3 Serial# 2504334802 Daikin One communicating thermostat - DTST-TOU-A Serial # EA2412601494 *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Reuse existing filter cabinet *Install new condensate pump *Start up and commission new system 12 Year Daikin manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
SOLD: 08/18/2025 10:32:10 PM - Option 3 - Cash/Check Pricing Install new Bryant HVAC system Equipment: Furnace-800SB42090M17 Bryant, Legacy, 80% AFUE, Single Stage, 4-Way Multipoise, MCT ECM, Gas Furnace, 90K, 17" width Serial# 3225A18097 AC-GA5SAN53000W 14.3 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 2.5 Ton, 208/230 Volt, 1 Phase, SW AC Serial# 1925C38674 Coil- CVAVA3017XMAEAAA Serial# 3025J20470 *Honeywell T4 Pro thermostat *AprilAire 1210 Media Air Cleaner Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *Connect to existing chimney liner *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
Perform cooling PMI on 1 RTU Replace x4 18x25x2 air filters for system Replace A50 motor belt Capacitors all within spec Coil clean Test run cooling Delta T - 20° Unit in good health at this time
Preventative maintenence inspection on two AC split systems. Change air filters and flush/clean drain pump. Test ran operation in cooling mode from thermostats. Water flushed outdoor coils to remove dirt and debris. Outdoor fan motor and compressor are operating within specs. Dual run capacitors are within specs. Systems are operating properly at the time of maintenance .
Service recall for continued freeze up Last two visits the blower was not running during an active call for cooling Today the blower was running normally. Pulled blower to investigate noise complaint. Blower wasn't fully in the track towards the rear of the housing, causing it to bounce around They explained condenser never stopped no matter what Removed cover on contactor. Found it welded shut Replaced contactor Cycled system 5 times from the thermostat to verify everything shuts off and restarts properly System operating normally at this time. Control board, blower motor, thermostat, and contactor are all new. Refrigerant charge was verified to be correct at first visit.
Perform cooling maintenance on RTU. Verify delta T is adequate - 20° Condenser coil is clean New 20x20x2 x4 today Belt AX54 in good condition left spare 52 per notes from previous job about motor tension, no issues were discovered with current setup plan to bring back ax54 for winter visit. No concerns at this time
Master suite 2nd floor system located in the third floor attic Install three Honeywell TZ electronic zone dampers
Had to insulate boots that were sweating
Two system rooftop package HVAC equipment cooling system maintenance, tune up, and cleaning. Replace all air filters on both systems Inspect fan belt and direct drive motors on both systems Water flush condenser coils and drain systems Test run all equipment in multi-stage cooling mode Inspect All electronics and electrical components Replace condensation drain trap on 1st floor system Second floor rooftop package equipment has a condenser fan in the beginning stages of failure with louder than normal motor shaft bearings Recommend replacing condenser fan motor and fan blade assembly Seth will prepare estimate for OEM Trane replacement parts on the next business day
Install two pump non-pressurized flow center and hose connection kit Reuse existing glycol antifreeze and set to +15° freeze protection with the new reservoir add new antifreeze as required for reservoir.
Install new Bryant HVAC system Equipment: Furnace- 926TC48080V17 Bryant, Preferred, 96" AFUE, Two Stage, VCT ECM, Gas Furnace, 80K, 17" width Serial# 1825A63315 AC- GA4SAN53600N 13.4 SEER2 Single-Stage Air Conditioner with Puron Advance Refrigerant, R-454B, 3 Ton Serial# 2825C16697 Coil- CVAVA3617XMA Serial# 1425J15474 *Honeywell T6 Pro thermostat Installation: *Reconnect to existing gas line and high voltage electric *Transition to existing supply and return ductwork *1" Air filter rack *Install new PVC vents for furnace *Start up and commission the new system Warranty: 10 Year Bryant manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)
Replacement warranty. South side unit thermostat programming allowed for overcooling for dehumidification. Noth side set to standard dehumidification while south was set to maximum. Masao explained it was a recurring thing but had never thought to call us before but this time noticed it was a bit colder and the system seemed to run longer. I explained the overcool to dehumidify concept and that it was possibly that it ran because of the higher humidity due to rain yesterday. Set south side thermostat to standard dehumidification setting and confirmed both thermostats were on same setting with 0F overcool allowance to dehumidify.