Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!
Overall Experience
Quality
Price
Convenience
My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!
Overall Experience
Quality
Price
Convenience
Overall Experience
Quality
Price
Convenience
Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)
Overall Experience
Quality
Price
Convenience
Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!
Overall Experience
Quality
Price
Convenience
Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.
Overall Experience
Quality
Price
Convenience
Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.
Overall Experience
Quality
Price
Convenience
We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!
Overall Experience
Quality
Price
Convenience
When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.
Overall Experience
Quality
Price
Convenience
Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.
Overall Experience
Quality
Price
Convenience
Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!
Overall Experience
Quality
Price
Convenience
Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.
Overall Experience
Quality
Price
Convenience
Gas heating preventative maintenance performed Check filter - popup2200 new today Clean flame sensor Inspect burners - rusty. Should be changed out next season Ohm test igniter: 48.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: ok due next season Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:05 Check delta T - 58° Furnace is in optimal running conditions
Daikin ductless split heat pump current fault code for out of refrigerant Lykens property management came to provide roof access Figured out which unit on the roof belongs to this system System is 100% out of refrigerant Customer has records from property management work orders regarding system not operating normally back to when they took possession of the space Maintenance filled the refrigerant without locating the leak and called it good Installation of the system is extremely poor quality Traced refrigerant line set through the restaurant next door's basement Unsure how the lines are ran to get to the indoor head between the restaurant wall and theirs Recommend replacing the system and the line set All of these issues are pre-existing to the customer taking possession of the space from the rental company
Performed heating maintenance on a 2005 Rheem 80% efficient single stage natural gas furnace 16x25x1 filter is in new condition Pulled flame sensor and cleaned Blower motor capacitor measuring 7.0mfd, rating is 7.5 Blower is very dirty Cleared inducer pressure switch port Performed run test and combustion analysis Furnace is overheating due to the dirty blower and shutting down on the high temperature limit Combustion test readings are healthy In an attempt to stop the high limit trips, increased blower speed to high and decreased gas pressure (2.3"wc, spec is 3.5") Run time is longer but still hits the high limit after 6 minutes of run time **Strongly recommend the blower cleaning we quoted** No safety concerns with the furnace, but it is not running at manufacturer's specifications due to the dirty blower Furnace may not be able to keep up on extremely cold days
Gas heating preventative maintenance performed Check filter - 16z25x4 new today owner supply Clean flame sensor Inspect burners - no concerns clean Ohm test igniter: 56.7 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: panel clean all on Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 4.0 Check amp draw on inducer motor:0.6 Check delta T - 42° Furnace is in optimal running conditions
Diagnostic Call Install T4 Pro Thermostat
Set gas pressures and adjusted fan speeds. Temp rise is in spec. Made customer aware that furnace needs a flue liner in the chimney.
Verified Humidifier set up Changed out Canister for low conductivity canister. AA80LC
Converted service call to heating maintenance Found high limit wire loose Reconnected, furnace operating normally Performed heating maintenance Pulled flame sensor and cleaned Pulled condensate trap and flushed with water High fire gas pressure set to 3.2"wc Temperature rise 62⁰ Low fire gas pressure 1.7" temp rise 49⁰ Inducer started backing up with water. Cleared debris from the drain tubing Double checked thermostat settings System operating within spec at this time Humidifier operating normally, no water leaks, water panel in good shape
Replace failed heater kit assembly. Test run operation of allcheat strips. Verified no loose connections and proper Amp draw. No issues found or suspected at this time.
Upon arrival, thermostat indicated the system was heating but the furnace was not operating. System was not showing any current codes. Code history only shows previous gas valve code. Test ran operation of furnace in thermostat heating test on low and high. Both initiated and worked properly for approximately 15-w0 minutes each. Inspected system for any loose wiring. None found. Inspected flue termination for ice buildup or other blockages. None found. Turned thermostat to normal heating mode and system turned on as it should after 5 minute wait period. System is currently operating with no issues found or suspected. After talking with Nate, he suspects it could be a bad control board butnaystem is currently running
Horizontal Rheem 80% single stage Diagnosed failed igniter. Replaced igniter Furnace operating normally at this time
SOLD: 11/14/2025 1:39:32 PM - Option 1 Install Daikin Aurora Ductless System *Variable Speed Heat Pump: Model #: RXT15AVJU9 Serial #: Y012067 15,000 BTU's 21 SEER2 - 12.2 EER2 - 10.5 HSPF2 Heating Operation at -13 Degrees & Above *Daikin Wall Mounted Air Handler Model #: FTXV15AVJU9 Serial #: Y068524 Installation: * Installation of electric wiring whip & disconnect * Start up and commission new system Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Upon arrival inspected system and found unit in EHC HHC fault condition. Inspected heat strips and found no major concerns. Test ran system and verified proper operation for both heat pump and electric heat. Electric Heating preventative maintenance performed Turn heat on at thermostat Check filter: Trane clean effects - clean Check volt and amp draw on heating elements: 240 60a strip pack Blower motor cap: n/a ECM Temp rise at — 26° heat pump alone - 56° HP & emergency heat Force defrost on outdoor unit reversing valve is operational Furnace and heat pump in optimal running conditions