725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Local Reviews
for columbus, oh

Rated 4.8 out of 5 stars based on 43 customer reviews

Exceptional Service

Seth is the best!! He’s very knowledgeable & friendly & takes time to explain everything that he did on the service call. He has come out to check our air conditioner & heater many times & we have hope he continues to come out & help us whenever we need service or repairs. Thank you Seth for being the BEST!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Honest and fair

My heat went out on a very cold weekend. I got 3 estimates and Westin was the most accurate and least expensive. The other 2 told me I needed a whole new system for $9500- 10,5000. All I needed was a part replaced. Westin was quick to respond and very friendly. I wouldn’t consider calling anyone else in the future and I’ve already recommended them to my friends and co-workers.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

service call

seemed costly

  • Overall Experience
  • Quality
  • Price
  • Convenience

The BEST service in town!

Westin Air is the best company around. Excellent customer service and reliability! Never had a bad experience and their staff and employees are professional, kind and so knowlegable!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Job as always

Thank you for all your help Westin Air!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Straight shooter

Came to evaluate my ac, gave me all the options including replacing the unit (it's 30 years old)

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always a great experience!

Seth and team at Westin are always professional, courteous, friendly and do a great job for a very fair price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Always Five Stars

Westin Air quoted and replaced the entire HVAC system in a previous home where we were tenants. They were professional, fair, thorough and timely, so when I needed work done on the AC in the home we just purchased, they were the first company I called. Seth was dispatched to our home quickly and gave me an honest assessment of the issue along with all the available repair options. I would highly recommend their services to anyone.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt, thorough and courteous installation. They were great!

Installation was completed as scheduled. The guys were courteous, prompt and professional. They completed on time, and the quality of their work was outstanding, testing all installed components to ensure 100% functionality. They took extra time to review operations of all components with us, and answered questions. Each of them were highly respectful, and we would recommend their team any time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

We requested a repairman to come to our house to check our furnace and water heater. They came promptly and I had a report within 2 hours. Thanks for the speed!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very responsive in fixing issues

When the inspector found a small (not dangerous) gas leak, a technician was out to fix it the next day. When we called because our furnace wasn't set up to use two-stage heat at installation, a technician came the same day to fix the issue.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Willing to work with you

Workers seemed like pretty good guys, always friendly. Willing to talk through the system and install with you if you had questions. If they didn't know the answer they would tell you, rather than make something up. I had a lot done to my house and it was over the holidays but I'd say they still made good time considering those conditions. Only been running my geo about a week but so far I'm pleased. Takes a lot for me to give 5 stars but they are up there.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Seth was friendly and knowledgeable and did a great job on both furnaces. He didn't mind my asking many questions since this was our first service on these furnaces. I would definitely recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service all the time

Seth does a great job every time he comes by to tune up on equipment. Great customer service. Great company. I would recommend to everybody.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for columbus, oh

Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 Clean flame sensor Water flush drain trap - June bug came out of it Ohm test igniter: 0.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today owner supply Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.47 Check amp draw on inducer motor:0.51 Check delta T - 46° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 Clean flame sensor Water flush drain trap Ohm test igniter: 48.7 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - 2” pvc no major concerns Set thermostat for heat Check amp draw on blower motor: 4.1 Check amp draw on inducer motor:0.53 Check delta T - 40-70 @ 46° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Daikin Fit heat pump system Replaced humidifier water panel (aprilaire 35) 20x25x4 filter is new, left the one we provide next to the air handler Washed outdoor unit, leaves were causing ice to dam at the bottom of the coil Found overheated wires on the electric heat kit contactor inside the air handler Daikin is going to get back with us as to what they will give us for warranty parts Tested auxiliary heat strips, they are all pulling 19A each Heat pump is running properly in heating mode Recommend putting white vinegar down the Condensate trap on thr air handler

Performed heating maintenance on a Daikin Fit heat pump system
Replaced humidifier water panel (aprilaire 35)
20x25x4 filter is new, left the one we provide next to the air handler
Washed outdoor unit, leaves were causing ice to dam at the bottom of the coil
Found overheated wires on the electric heat kit contactor inside the air handler
Daikin is going to get back with us as to what they will give us for warranty parts
Tested auxiliary heat strips, they are all pulling 19A each
Heat pump is running properly in heating mode
Recommend putting white vinegar down the Condensate trap on thr air handler Performed heating maintenance on a Daikin Fit heat pump system
Replaced humidifier water panel (aprilaire 35)
20x25x4 filter is new, left the one we provide next to the air handler
Washed outdoor unit, leaves were causing ice to dam at the bottom of the coil
Found overheated wires on the electric heat kit contactor inside the air handler
Daikin is going to get back with us as to what they will give us for warranty parts
Tested auxiliary heat strips, they are all pulling 19A each
Heat pump is running properly in heating mode
Recommend putting white vinegar down the Condensate trap on thr air handler

Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Trane furnace. 16x25x4 air filter is new today. Clean flame sensor and check ignitor. Blower capacitor is good. Visual inspection of burners. Test ran in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. 4" galvanized B-vent in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Nate G.

Nate G. Job Checkin

Replaced gas control valve under factory parts warranty Set Manifold pressure to 3.0"wc Temperature rise is 60⁰ Needs a Honeywell popup 2400 filter

Replaced gas control valve under factory parts warranty
Set Manifold pressure to 3.0"wc
Temperature rise is 60⁰

Needs a Honeywell popup 2400 filter

Jason D.

Jason D. Job Checkin

SOLD: 10/30/2025 9:12:24 AM - Option 1 Install New Bryant HVAC System Bryant Preferred 96 2-Stage Gas Furnace Model #: 926TC30040V14A-A Serial #: 3825A48819 40,000 BTU's - 96% AFUE Bryant Single-Stage Air Conditioner Model #: GA5SAN51800WAAAA Serial #: 0725X48163 1.5 Ton - 15 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA2414XMA Serial #: 2425J85461 Installation: * Plenum, Return Air Drop and necessary ductwork connections * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Honeywell T4 Pro Thermostat * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


Graham M.

Graham M. Job Checkin

Electric Heating preventative maintenance performed Turn heat on at thermostat 16x25x1 filter clean Check volt and amp draw on heating elements: Blower motor cap: ECM no concerns Temp rise at — for emergency heat 42° Force defrost on outdoor unit reversing valve is operational Furnace and heat pump in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - due soon Clean flame sensor Ohm test igniter: 54.8 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new recently Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.43 Check amp draw on inducer motor:0.72 Check delta T - 63° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Goodman 90% efficient two stage furnace Hot surface igniter failed Got verbal authorization from Tabitha to replace igniter Installed new igniter Furnace operating normally at this time. 16x25x1 filter needs replaced ASAP


Jason D.

Jason D. Job Checkin

SOLD: 11/05/2025 3:32:59 PM - Option 1 Install New Bryant HVAC System Bryant Preferred 2-Stage Gas Furnace Model #: 927TA48080V17A-A Serial #: 4325A60962 80,000 BTU's - 97% AFUE Bryant Single-Stage Air Conditioner Model #: GA5SAN53000WAAAC Serial #: 4025C13251 2.5 Ton - 14.3 SEER2 Puron Advance Refrigerant, R-454B Matching Cased Coil: CVAVA3017XMAEAAA Serial #: 1625J54548 Installation: * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system * Honeywell T6 Pro Thermostat * 1" Standard Filter Rack Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 11/05/2025 3:32:59 PM - Option 1

Install New Bryant HVAC System 
Bryant Preferred 2-Stage Gas Furnace
Model #: 927TA48080V17A-A
Serial #: 4325A60962
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN53000WAAAC
Serial #: 4025C13251
2.5 Ton - 14.3 SEER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3017XMAEAAA
Serial #: 1625J54548
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Honeywell T6 Pro Thermostat
* 1" Standard Filter Rack
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

SOLD: 11/05/2025 3:32:59 PM - Option 1

Install New Bryant HVAC System 
Bryant Preferred 2-Stage Gas Furnace
Model #: 927TA48080V17A-A
Serial #: 4325A60962
80,000 BTU's - 97% AFUE
Bryant Single-Stage Air Conditioner
Model #: GA5SAN53000WAAAC
Serial #: 4025C13251
2.5 Ton - 14.3 SEER2
Puron Advance Refrigerant, R-454B
Matching Cased Coil: CVAVA3017XMAEAAA
Serial #: 1625J54548
 
Installation:
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
* Honeywell T6 Pro Thermostat
* 1" Standard Filter Rack
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts & Compressor Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Brandon P.

Brandon P. Job Checkin

Free second opinion on heat exchanger shows that there are no issues with the heat exchanger. Tests performed were visual inspection with borescope camera on inside and outside of heat exchanger. No visual issues. Followed by combustion analysis. Combustion analysis did not show any issues. CO AF reading 24ppm. Normal readings are less than 100, with anything under 400ppm acceptable. Used combustion analyzer to test for CO in the supply ductwork, and basement area surrounding the furnace. Both came back with 0PPM CO detected. Pictures of combustion uploaded to file. Furnace is combustion is within specifications and safe to operate.

Free second opinion on heat exchanger shows that there are no issues with the heat exchanger. Tests performed were visual inspection with borescope camera on inside and outside of heat exchanger. No visual issues. Followed by combustion analysis. Combustion analysis did not show any issues. CO AF reading 24ppm. Normal readings are less than 100, with anything under 400ppm acceptable. Used combustion analyzer to test for CO in the supply ductwork, and basement area surrounding the furnace. Both came back with 0PPM CO detected. Pictures of combustion uploaded to file. Furnace is combustion is within specifications and safe to operate. Free second opinion on heat exchanger shows that there are no issues with the heat exchanger. Tests performed were visual inspection with borescope camera on inside and outside of heat exchanger. No visual issues. Followed by combustion analysis. Combustion analysis did not show any issues. CO AF reading 24ppm. Normal readings are less than 100, with anything under 400ppm acceptable. Used combustion analyzer to test for CO in the supply ductwork, and basement area surrounding the furnace. Both came back with 0PPM CO detected. Pictures of combustion uploaded to file. Furnace is combustion is within specifications and safe to operate.

Brandon P.

Brandon P. Job Checkin

Free second opinion on heat exchanger shows that there are no issues with the heat exchanger. Tests performed were visual inspection with borescope camera on inside and outside of heat exchanger. No visual issues. Followed by combustion analysis. Combustion analysis did not show any issues. CO AF reading 24ppm. Normal readings are less than 100, with anything under 400ppm acceptable. Used combustion analyzer to test for CO in the supply ductwork, and basement area surrounding the furnace. Both came back with 0PPM CO detected. Pictures of combustion uploaded to file. Furnace is combustion is within specifications and safe to operate.

Free second opinion on heat exchanger shows that there are no issues with the heat exchanger. Tests performed were visual inspection with borescope camera on inside and outside of heat exchanger. No visual issues. Followed by combustion analysis. Combustion analysis did not show any issues. CO AF reading 24ppm. Normal readings are less than 100, with anything under 400ppm acceptable. Used combustion analyzer to test for CO in the supply ductwork, and basement area surrounding the furnace. Both came back with 0PPM CO detected. Pictures of combustion uploaded to file. Furnace is combustion is within specifications and safe to operate. Free second opinion on heat exchanger shows that there are no issues with the heat exchanger. Tests performed were visual inspection with borescope camera on inside and outside of heat exchanger. No visual issues. Followed by combustion analysis. Combustion analysis did not show any issues. CO AF reading 24ppm. Normal readings are less than 100, with anything under 400ppm acceptable. Used combustion analyzer to test for CO in the supply ductwork, and basement area surrounding the furnace. Both came back with 0PPM CO detected. Pictures of combustion uploaded to file. Furnace is combustion is within specifications and safe to operate.

Nate G.

Nate G. Job Checkin

No heat call, 2016 Trane S9V2 two stage 96% efficient Stored fault code for plugged condensate Converted to silver heating maintenance call Performed heating maintenance Pulled condensate trap and flushed Pulled flame sensor and cleaned Pulled burners and cleaned Intake full of debris, cleared it out Checked humidifier, operating normally, water panel OK, no water leaks at this time 20x25x1 Filter is new High fire gas pressure set to 3.5"wc Low fire gas pressure set to 1.7"wc Furnace operating normally at this time.

No heat call,  2016 Trane S9V2 two stage 96% efficient
Stored fault code for plugged condensate
Converted to silver heating maintenance call
Performed heating maintenance 
Pulled condensate trap and flushed 
Pulled flame sensor and cleaned 
Pulled burners and cleaned 
Intake full of debris, cleared it out
Checked humidifier, operating normally, water panel OK, no water leaks at this time 
20x25x1 Filter is new
High fire gas pressure set to 3.5"wc
Low fire gas pressure set to 1.7"wc
Furnace operating normally at this time. No heat call,  2016 Trane S9V2 two stage 96% efficient
Stored fault code for plugged condensate
Converted to silver heating maintenance call
Performed heating maintenance 
Pulled condensate trap and flushed 
Pulled flame sensor and cleaned 
Pulled burners and cleaned 
Intake full of debris, cleared it out
Checked humidifier, operating normally, water panel OK, no water leaks at this time 
20x25x1 Filter is new
High fire gas pressure set to 3.5"wc
Low fire gas pressure set to 1.7"wc
Furnace operating normally at this time.

Graham M.

Graham M. Job Checkin

Replaced all 9 filters Cleaned all flame sensors Only one of the humidifier water panels needed replaced Run tested systems Verified correct operation Tested humidifiers No water leaks present at this time Pool house basement is flooding again, reported this to Roy. Also noted the master bedroom system (horizontal York off the theater room on the 3rd floor) has a large amount of oil on the suction line for the AC Going through service history looking to see if there are previous calls for a refrigerant leak (there are none), found there was a drain clog over the summer. Recommend adding a wet switch under the drain line to shut everything down in the event of another backup. This pertains to AC condensate in the summer and humidifier drain in the winter. No concerns found pertaining to heating operation


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a 2022 Tempstar 96% efficient two stage natural gas furnace Filter appears new Aprilaire #35 water panel inside the 600M humidifier is in good shape Verified correct operation and no water leaks with the humidifier Pulled and cleaned the flame sensor Blower wheel is clean Condensate trap is clear and flowing properly No water leaks present inside the furnace or external drain piping Intake and exhaust piping are leak free Run tested furnace High fire gas pressure is 3.5"wc Temperature rise is 49⁰ (spec is 40-70) Low fire gas pressure is 1.7" Temperature rise is 42⁰ (spec is 30-60) Furnace is in great shape and operating perfectly with manufacturer's specifications at this time No concerns found on today's visit