Overall Experience
Quality
Price
Convenience
Gas heating preventative maintenance performed Check filter - 20x25x1 8/10/25 Clean flame sensor Ohm test igniter: 58.2 Inspect wiring for loose connections and/or hot spots - none found Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.2 Check amp draw on inducer motor:0.9 Check delta T - 59° Furnace is in optimal running conditions
Performed cooling maintenance Filter is good Blower is clean Drain is clear No signs of water leaks from the furnace that may have developed during heating season after our last visit Refrigerant charge is in spec 9⁰ subcool Capacitor measured 40 under load and 45 without load Removed top of unit and washed outdoor coil from inside out System is in good shape and running within factory specifications at this time
Upon arrival inspector inspected furnace and found locked out on pressure switch code. Is cycled furnace for heat and inducer motor would not start. Shook wiring harness and noticed it kicks on intermittently. Wiring harness had loose pins titan connector and retry heat call. Furnace came on and was running no problem after fixing pins.
Furnace maintenance inspection performed Inspect filter:20x25x1 clean Inspect burners: Clean no concerns Ohm ignitor: 46 ohms Clean flame sensor Inducer amps: 0.27 Blower Motor amps: 2.20 All wiring OK Humidifier: n/a Temperature rise: 58⁰ propane 30⁰ heat pump Furnace is running in optimum condition.
Tempstar high efficiency heating and cooling Maintenance replacement hot surface ignitor and flame sensor Lancaster Newark Road Millersport Ohio 43046