Great customer service!

Best customer service. Seth was thorough and efficient. He took his time to explain things about my air conditioning unit to me. I highly recommend!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Furnace Maintenance

I explained what happened, team was able to find and fix problem. They also took the time to educate me on my Furnace so that if another problem occurs I can help them pin point the problem, potentially saving me a service call charge. I have been using Westin for almost four years, great people, highly recommend.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Visit on 12/7/15

Had a heat problem over the weekend. Westin team was able to help me over the phone (early on a Sunday morning no less) so I could avoid the more expensive weekend visit charge. They then came out early Monday morning to check my heat pump unit to make sure everything was working properly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for centerburg, oh

seth p.

seth p. Job Checkin

Increase continuous fan mode blower speed from 1 to 10 on 25 speed Bryant blower Confirm cooling mode blower speed set to 11 for low and high stages Replace 16x25x4 plated media filter homeowner already had on site


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on air to air heat pump and geo thermal heat pump Both systems operating within specification Dehumidifier filter clean Put drain tablets in dehumidifier, and both indoor coil pans Sprayed both indoor coils with no rinse cleaner


Nate G.

Nate G. Job Checkin

System operating normally upon arrival Customer described turning system off and on multiple times to get it to work. Found a smashed earwig inside the contactor. Cycling the system like that jostled it free, allowing the system to function again. Complaint of second floor not getting any airflow Interested in a two zone mini split


Jason D.

Jason D. Job Checkin

Install new Daikin air conditioner Air Conditioner: DC3SEN6010 Coil: CAPTA6030D3 *Reuse existing thermostat *Reconnect to existing high voltage electric *Transition to existing supply and return ductwork *Dragonfly Furnace Adapter *Start up and commission new system 12 Year Daikin manufacturers parts warranty (Annual maintenance must be performed) 2 Year Westin Air labor warranty (Annual maintenance must be performed)

Install new Daikin air conditioner
Air Conditioner: DC3SEN6010
Coil: CAPTA6030D3
*Reuse existing thermostat
*Reconnect to existing high voltage electric
*Transition to existing supply and return ductwork
*Dragonfly Furnace Adapter
*Start up and commission new system
12 Year Daikin manufacturers parts warranty (Annual maintenance must be performed)
2 Year Westin Air labor warranty (Annual maintenance must be performed)

seth p.

seth p. Job Checkin

Upon arrival today the system was turned on and set to 75 and and maintaining 75 on a normal cycle. Air filter is very dirty and may have played a part in the extreme temperatures in the past few days. Installed replacement 16x25x1 plated filter from truck stock, inspect and run test outdoor equipment. Outdoor coils are in very good condition and no cleaning is required. Electrical compartment has rodent activity including a dead mouse on the contactor relays, paper shreds and droppings throughout. Test run outdoor equipment in cooling mode second stage, refrigerant pressures are within specs 25 UF fan motor capacitor and 25 UF compressor capacitor are both below specs creating underpowered equipment and reduce capacity in the most extreme temperatures of the year. Recommend replacing both motor run capacitors Estimate has been sent attached to today's invoice receipt and is awaiting approval by homeowners Thermostat had nine pages of logged diagnostic alerts. Several pertain


Nate G.

Nate G. Job Checkin

Warranty for the modifications we made to the system Only fault code was high pressure lock out Cleared faults Put system into charge mode Ended up recovering at least a pound of refrigerant System holding a solid 8⁰ subcool Ended up running the thing for over an hour taking back tiny amounts of charge into a recovery cylinder


seth p.

seth p. Job Checkin

34-year-old train r22 heat pump is very low on refrigerant charge. The system is not cycling on any safety switches and is continuing to run at 34 to 36 PSI suction with intermittent freezing occurring Estimate prepared for the homeowner for a worst case scenario was approximately $1,425 for 15 lb of refrigerant with labor and leak stop. Homeowner understands he will only be billed for the used amount but has declined repairs at this time and would like a replacement estimate and financing information If a refrigerant charge is desired within the next 30 days no additional trip charges will be billed. The estimate will be for labor including leak stop and up to 15 lb of refrigerant. Homeowner understands that the refrigerant will be build by the quarter pound and the bill will be adjusted at the end. The mandatory authorized estimate is a worst case scenario if all 15 lb of refrigerant is required


seth p.

seth p. Job Checkin

Confirmed locked up compressor pulling 98 amps with replacement capacitor and super boost installed Compressor, compressor capacitor, liquid line filter dryer, TXV, 81 Oz new r410a all need to be replace. Air coil needs duct board dropped removed for heavy duty shop vac and chemical coil cleaning, pressurized ground loop system contains alcohol and both pumps are confirmed operational however pressure has been reduced to below 10 psi. Ground loops need repressurized with house water pressure. Refrigerant pressure is holding at 210 PSI indicating a probably mostly sealed system however due to the nature of the compressor mechanical lockout all refrigerant needs replaced including a acid scavenger treatment Seth will follow up with parts distributor and prepare estimate ASAP


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a Trane two stage heat pump Filter is clean Blower is clean Drain is clear Wiring is secure and no signs of overheating Outdoor coil is clean Capacitor tested in specification Wiring is secure and no signs of overheating A mouse showed itself while testing the unit. Thankfully, there isn't any chew marks on the wiring yet. Recommend pest control to get rid of them. Refrigerant charge is in specification Complaints of noise from the heat pump since day 1 Interested in Daikin heat pump and possibly switching to a dual fuel system since there is propane.


Nate G.

Nate G. Job Checkin

Waterfurnace geothermal diagnostic System locked out on condensate safety Cleared drain and put Condensate drain treatment tablets in the coil drain pan Reusable filter that was being used is not sized properly. As a result, edges of the coil were dirty, which contributed to the drain clogging Sprayed no-rinse coil cleaner on the air coil All of these issues would be prevented with a regular maintenance. Our plan includes a correct 28x30x2 filter on each visit We also make sure the drain is clear System is operating normally at this time

Waterfurnace geothermal diagnostic 
System locked out on condensate safety
Cleared drain and put Condensate drain treatment tablets in the coil drain pan
Reusable filter that was being used is not sized properly. 
As a result, edges of the coil were dirty, which contributed to the drain clogging
Sprayed no-rinse coil cleaner on the air coil 

All of these issues would be prevented with a regular maintenance.  Our plan includes a correct 28x30x2 filter on each visit
We also make sure the drain is clear

System is operating normally at this time

seth p.

seth p. Job Checkin

Service department warranty Condenser fan motor intermittently operating but running like normal at full speed upon arrival today Cell phone video shows the motor is powered up in some fashion but barely spinning Homeowner is not concerned with any multi-stage or heat pump heating mode operation of the equipment. They have natural gas in the house now. Rewire controls to bypass defrost control board fan cycling relay on the T1 Hi voltage circuit and rewire to bypass two outdoor thermostats on the T2 fan circuit. The new outdoor fan motor installed 2 days ago is now wired directly to the contactor to run at high speed anytime the compressor is on. Confirm correct motor and capacitor wiring


seth p.

seth p. Job Checkin

1991 Trane XL 1200 17 seer 5 ton heat pump Locked up outside two speed condenser fan motor Install replacement condenser fan motor and capacitor Diversitech WG840465 1/3 horsepower 208/230 condenser fan motor and 5 UF 370 volt power supply capacitor Homeowner is not ready today but would like an estimate for new air conditioning equipment. The Rheem\Ruud gas furnace is 1 to 2 years old


seth p.

seth p. Job Checkin

2024 water furnace 5 series split system geothermal paired with carrier horizontal high efficiency 90 plus gas furnace Install replacement air filter provided by homeowner AprilAire 210 Confirm correct blower speeds and minor dusting of furnace Inspect indoor air coil and water flush drain trap and drain pan assembly, FC2 non-pressurized flow center running in excellent condition Confirm glycol test at 25% with 15° freeze protection Inspect and run test all equipment in multi-stage heat pump cooling mode. High stage cooling mode producing 44° supply temperature 11 PSI pressure drop 23 to 12 at 50.1°f Scan Aurora Base communications for diagnostic service codes, confirm correct operation with 11 x E99 system reset power cycles since last scan Confirm DHW operation at 113° combined with AID tool confirmation of relay activation All equipment is clean safe and ready for cooling season ***Unfortunately the non pressurized flow center reservoir is sitting on the concrete floor an


Brandon P.

Brandon P. Job Checkin

2004 Lennox AC is operating properly, but in fair condition and showing age. 16x25x1 air filter in good. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Outdoor disconnect was off due to previous fan issues. Once inside AC electrical panel, a rodents nest was found and many of the low voltage and high voltage wiring was chewed up and showing bare wire. Performed wiring repairs to remove damaged wire and reconnect. Due to age and condition of contactor, we replaced that aswell wich is a candidate for why the fan would not shut off. After wiring repairs and contactor replacement, test ran AC to check refrigerant pressures. R-22 refrigerant pressures are within spec. Exact pressures and temperatures on photos. Dual run capacitor is within spec. Condenser coils are in clean condition. System is operating properly, but due to age, an estimate of lifespan cannot be said. Recommend preparing for replacement in the near future.

2004 Lennox AC is operating properly, but in fair condition and showing age. 16x25x1 air filter in good. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Outdoor disconnect was off due to previous fan issues. Once inside AC electrical panel, a rodents nest was found and many of the low voltage and high voltage wiring was chewed up and showing bare wire. Performed wiring repairs to remove damaged wire and reconnect. Due to age and condition of contactor, we replaced that aswell wich is a candidate for why the fan would not shut off. After wiring repairs and contactor replacement, test ran AC to check refrigerant pressures. R-22 refrigerant pressures are within spec. Exact pressures and temperatures on photos. Dual run capacitor is within spec. Condenser coils are in clean condition. System is operating properly, but due to age, an estimate of lifespan cannot be said. Recommend preparing for replacement in the near future.

Brandon P.

Brandon P. Job Checkin

System is operating properly and within refrigerant and air temperature specifications. Refrigerant pressures and temperatures are as follows, High 250psi with 10F Subcool, low 105psi with 12F Superheat. Delta t of air across indoor coil is 19F with new filter installed. Return temp 67F, supply air 48F. Tested indoor air coil for any refrigerant leaks with electronic refrigerant detector, none found. No issues were found or suspected with heat pump, indoor coil, or refrigeration.