Brandon P.

Brandon P. Job Checkin

Preventative maintenence inspection on Lennox high efficiency furnace running in great condition. 16x25x1 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Run test unit in heating mode. Temperature rise is within specs. Blower and inducer motors tested good. Pvc flue vents in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 226 ok Clean flame sensor Inspect burners - mildy rusty brush clean Ohm test igniter: 46.2 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: clean Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 2.03 Check amp draw on inducer motor:0.28 Check delta T - 54° Furnace is in optimal running conditions


Graham M.

Graham M. Job Checkin

Gas heating preventative maintenance performed Check filter - 216 ok Clean flame sensor Inspect burners - no concerns Ohm test igniter: 56.6 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.5 Check amp draw on inducer motor:0.87 Check delta T - 68° Furnace is in optimal running conditions


Nate G.

Nate G. Job Checkin

Performed heating maintenance on a Trane single stage 80% efficient natural gas furnace Cleaned flame sensor 20x25x1 Filter is in good condition Blower is clean Removed blower and cut open the return to the filter rack to allow for maximum airflow across the filter Run tested furnace Gas pressure set to 3.5"wc Adjusted blower speed from 6 down to 4 Temperature rise 47⁰ (spec 30-60⁰) Flue pipe in good shape Furnace is operating within factory specs at this time

Performed heating maintenance on a Trane single stage 80% efficient natural gas furnace 
Cleaned flame sensor
20x25x1 Filter is in good condition
Blower is clean
Removed blower and cut open the return to the filter rack to allow for maximum airflow across the filter
Run tested furnace
Gas pressure set to 3.5"wc
Adjusted blower speed from 6 down to 4
Temperature rise 47⁰ (spec 30-60⁰)
Flue pipe in good shape
Furnace is operating within factory specs at this time Performed heating maintenance on a Trane single stage 80% efficient natural gas furnace 
Cleaned flame sensor
20x25x1 Filter is in good condition
Blower is clean
Removed blower and cut open the return to the filter rack to allow for maximum airflow across the filter
Run tested furnace
Gas pressure set to 3.5"wc
Adjusted blower speed from 6 down to 4
Temperature rise 47⁰ (spec 30-60⁰)
Flue pipe in good shape
Furnace is operating within factory specs at this time

Jason D.

Jason D. Job Checkin

Changed the settings on her nest thermostat to humidify in heat mode. Also turned water pressure down on the saddle valve.


Jason D.

Jason D. Job Checkin

SOLD: 10/20/2025 11:31:40 AM - Option 1 Install New Bryant Single Two Stage Gas Furnace Model #: 927TA60080V21 Serial #: 4025A45376 80,000 BTU’s - 97% AFUE Installation: * Aprilaire 1210 (20X25) Media Air Cleaner * Additional Services - New PVC furnace vents. Level 1 * Reconnect to existing gas line and high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system Warranty: 20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


SOLD: 10/20/2025 11:31:40 AM - Option 1

Install New Bryant Single Two Stage Gas Furnace
Model #: 927TA60080V21
Serial #: 4025A45376
80,000 BTU’s - 97% AFUE
 
Installation:
* Aprilaire 1210 (20X25) Media Air Cleaner
* Additional Services - New PVC furnace vents. Level 1
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
 

SOLD: 10/20/2025 11:31:40 AM - Option 1

Install New Bryant Single Two Stage Gas Furnace
Model #: 927TA60080V21
Serial #: 4025A45376
80,000 BTU’s - 97% AFUE
 
Installation:
* Aprilaire 1210 (20X25) Media Air Cleaner
* Additional Services - New PVC furnace vents. Level 1
* Reconnect to existing gas line and high voltage electric
* Transition to existing supply and return ductwork
* Start up and commission new system
 
Warranty:
20 Year Bryant manufacturers Heat Exchanger Warranty (Annual maintenance must be performed)
10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Jason D.

Jason D. Job Checkin

WARRANTY

WARRANTY WARRANTY

Brandon P.

Brandon P. Job Checkin

2017 Trane high efficiency furnace running in great condition. Cleaned Trane Clean Effects filters. Clean flame sensor and check ignitor ohms. Flush condensation trap. Humidifier pad in good condition, damper opened, run test during heating mode. Run test unit in heating mode. Delta t of 50F with supply temp of 123F, spec Delta t of 40-70F. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing. Blower motor and inducer motor running within specs. Unit is operating properly, efficiently and ready for Winter


Nate G.

Nate G. Job Checkin

Performed cooling maintenance on new Bryant AC system 16x25x4 filter is good Drain clear Blower OK Line set insulation good Tore down and washed outdoor coil Checked refrigerant charge, running 5.3⁰ subcool, spec is 8⁰ Added a few ounces of R454b refrigerant to get 8⁰ subcool System is clean and running within factory specs at this time.


Brandon P.

Brandon P. Job Checkin

Replace two elbow fittings and approximately one foot of pipe. New 26 gauge pipe and elbows used for replacement. Three screws n each fitting to ensure nothing comes apart in the future. Light water heater and set slightly lower than previous setting per Ron's request. Water heater vent is good and safe for use.

Replace two elbow fittings and approximately one foot of pipe. New 26 gauge pipe and elbows used for replacement. Three screws n each fitting to ensure nothing comes apart in the future. Light water heater and set slightly lower than previous setting per Ron's request. Water heater vent is good and safe for use. Replace two elbow fittings and approximately one foot of pipe. New 26 gauge pipe and elbows used for replacement. Three screws n each fitting to ensure nothing comes apart in the future. Light water heater and set slightly lower than previous setting per Ron's request. Water heater vent is good and safe for use.

Nate G.

Nate G. Job Checkin

Diagnosed failed capacitor Replaced 40/7.5 dual run cap Cleaned up some rodent damaged wiring System operating normally at this time


Jeramie T.

Jeramie T. Job Checkin

See Notes

See Notes See Notes

Nate G.

Nate G. Job Checkin

Performed cooling maintenance on a Trane system Aprilaire 216 filter is still good Shut down humidifier Blower is clean Drain is clear Visual inspection of furnace for any water leaks that may have developed since the fall checkup Put air diagnostic probes in the return and supply ducts Connected refrigerant diagnostic probes to outdoor unit Specification calls for 8⁰ of liquid line subcooling, actual measurement was 0⁰ Discussed options for leak search Decided to go with top off and dye System took 1lb of R410a Now running 8⁰ subcool Capacitor tested 38.5 under load with the Compressor running, this is in specification tolerance Condenser coil is clean Fan blade has no signs of damage or imbalance Wiring is tight and no signs of damage or overheating

Performed cooling maintenance on a Trane system
Aprilaire 216 filter is still good
Shut down humidifier
Blower is clean
Drain is clear
Visual inspection of furnace for any water leaks that may have developed since the fall checkup
Put air diagnostic probes in the return and supply ducts
Connected refrigerant diagnostic probes to outdoor unit
Specification calls for 8⁰ of liquid line subcooling, actual measurement was 0⁰
Discussed options for leak search 
Decided to go with top off and dye
System took 1lb of R410a
Now running 8⁰ subcool 
Capacitor tested 38.5 under load with the Compressor running, this is in specification tolerance
Condenser coil is clean
Fan blade has no signs of damage or imbalance
Wiring is tight and no signs of damage or overheating Performed cooling maintenance on a Trane system
Aprilaire 216 filter is still good
Shut down humidifier
Blower is clean
Drain is clear
Visual inspection of furnace for any water leaks that may have developed since the fall checkup
Put air diagnostic probes in the return and supply ducts
Connected refrigerant diagnostic probes to outdoor unit
Specification calls for 8⁰ of liquid line subcooling, actual measurement was 0⁰
Discussed options for leak search 
Decided to go with top off and dye
System took 1lb of R410a
Now running 8⁰ subcool 
Capacitor tested 38.5 under load with the Compressor running, this is in specification tolerance
Condenser coil is clean
Fan blade has no signs of damage or imbalance
Wiring is tight and no signs of damage or overheating

Graham M.

Graham M. Job Checkin

Cooling preventative maintenance performed Check filter - 16x25x1 Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 35+5 @ 34.74+4.87 Check OD fan Amp - 0.61 Check compressor Amp - 4.31 Verify pressures and HP-SC/LP-SH 321-12° / 119-16° Delta T - 19° The Air handler and AC are in optimal running conditions.


Brandon P.

Brandon P. Job Checkin

2018 ICP AC running in great condition. AA210 filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 19F with supply temp of 50F. Refrigerant pressures are within spec. Outdoor fan motor and compressor are operating within specs. Water flush outdoor coils to remove dirt and debris. System is operating properly, efficiently and ready for Summer.

2018 ICP AC running in great condition. AA210 filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 19F with supply temp of 50F. Refrigerant pressures are within spec. Outdoor fan motor and compressor are operating within specs. Water flush outdoor coils to remove dirt and debris. System is operating properly, efficiently and ready for Summer.