brought ac/furance from them and any service needed have always been taken care of
Seth and Melissa were wonderful to work with, I really appreciated how fast Melissa arranged to have my furnace started after my many delays with the gas company and the cold weather arriving in 2 days. Thanks very much and happy holidays.
Cooling preventative maintenance performed Check filter - 16x25x1 Check coil for any buildup debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 35+5 @ 34.74+4.87 Check OD fan Amp - 0.61 Check compressor Amp - 4.31 Verify pressures and HP-SC/LP-SH 321-12° / 119-16° Delta T - 19° The Air handler and AC are in optimal running conditions.
2018 ICP AC running in great condition. AA210 filter in good condition. Visual inspection of indoor coil. Flush drain pan and drain lines. Run test unit in cooling mode from thermostat. Delta t of 19F with supply temp of 50F. Refrigerant pressures are within spec. Outdoor fan motor and compressor are operating within specs. Water flush outdoor coils to remove dirt and debris. System is operating properly, efficiently and ready for Summer.
Cooling preventative maintenance performed Check filter - 16x25x1 Check coil for any buildup or debris in drain pan and flush with water Set up thermometers Rinse down outdoor coil with garden hose Check capacitor MFD - 40 @ 39.51 Check OD fan Amp - Check compressor Amp - Verify pressures and HP-SC/LP-SH 324/8° 128/12° (tarp over cage to reach desired 325 head pressure as described on charging chart.) Delta T - 18° The Air handler and AC are in optimal running conditions. Unit was low 1lb r410a believed to be low since install advised homeowner we will access status next year.
2017 Bryant evolution communicating furnace and thermostat with single stage non-communicating air conditioner Initial cooling system test running will not turn on 24v condenser or initiate proper blower speeds for cooling mode Bryant evolution communicating thermostat will run the air conditioner in cooling mode in service test mode and will produce 51° supply temperature confirming all of the equipment, aside from the communicating thermostat controls, are functioning properly Power cycle and reboot evolution control, confirm online connection for system automatic updates, cycle through equipment fault codes, return equipment to normal operation. Thermostat and equipment is running correctly in cooling mode at this time however homeowners have expressed concern about the humidifier operation which coincides with multiple years of service codes stating failed humidity sensor on the evolution control. Recommend upgrading the Bryant evolution touch screen communicating thermosta
Locked up 1/5 horsepower 115 volt indoor air blower motor Install universal truck stock motor set to low and medium low with new replacement 5 UF motor run capacitor Test run crawlspace condensate pump with two buckets of water
2017 Trane AC running in great condition. Trane Clean Effects filter cleaning. Visual inspection of indoor coil. Flush drain pan and drain lines. Humidifier damper is closed. Run test unit in cooling mode from thermostat. Delta t of 20F with supply temp of 51F. Refrigerant pressure are within spec. High 240psi with 8F SC, low 125psi with 14F SH. System is operating properly, efficiently and ready for Summer.
Install New Bryant Air Conditioner and Coil AC: 134SAN03600N Serial #: 1025C55675 3 Ton 15 SEER2 – 11.5 EER2 Coil: CVAVA3621XMA Serial #: 0925J19938 Installation: * Reconnect to existing high voltage electric * Transition to existing supply and return ductwork * Start up and commission new system Warranty: 10 Year Bryant manufacturers Compressor Warranty (Annual maintenance must be performed) 10 Year Bryant manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)
Replacement warranty. Bad contactor causing thermostat to show error code. Replace contactor and test run.
Canceled by the homeowner at the call ahead. He's going to charge the nest thermostat and retry. The unit was installed in a four-wire manner with no C common wire but has worked for years
Diagnosed no power to the nest thermostat Diagnose loud booming noise in flame roll out at startup No power to the thermostat was caused by a faulty blower motor causing the primary limit to shut down during overheating and result no power to the thermostat went overheated Booming noise and roll out is caused by a failed pressure regulator in the gas valve. Slow opening gas valve is dumping 4.9"wc full volume at startup and running at 4.5 but cannot be adjusted. Install diversitech brand 1/2 horsepower indoor blower motor Install OEM Armstrong Air intermittent pilot spark ignition gas valve (White-Rodgers retrofit) Test run heat mode at 138 and confirm temperature rise is within the 55 to 85 furnace specs Blower high speed set to heating medium high set to cooling
Upon arrival inspected furnace and found no major concerns. Inspected burners, clean but flame sensor was dirty, cleaned flame sensor and flushed drain trap it was full of rust and sediment. Inform homeowner furnace is operational and now has been cleaned, there should not be any more issues due to lack of maintenance.
2017 Trane high efficiency furnace running in great condition. Trane Clean Effects filter cleaning performed. Clean flame sensor and check ignitor ohms. Blow out condensation trap. Humidifier pad in good condition, damper opened, run test during heating mode. Run test unit in heating mode from thermostat. Delta t of 49F with supply temp of 123F, spec Delta t of 40-70F. Blower motor and inducer motor running within spec. 2" pvc flue in good condition and no sign of leaks. 0PPM CO detected during testing in basement. Unit is operating properly, efficiently and ready for Winter.
System not operating upon arrival. Discovered 60a and 30a breakers OFF at air handler.Engaged breakers and System became operational. AMP Draw on ecm blower .9a and heating elements 20.1a. Discharge air 123° with intake of 51°. CYCLED system multiple times and no issues. System is operating normal at this time.Filter 20x25x1 and like new.Contacters are burnt needs replacement single and dual in air handler.
Performed heating maintenance on a Trane 96% efficient two stage natural gas furnace Filter new Humidifier water panel good for this heating season... opened water supply valve and run tested, no leaks. Opened bypass damper and set humidity to level 5 on the automatic controller Pulled and cleaned flame sensor Blew out Condensate trap Ran combustion test. Readings within nominal range. No carbon monoxide present in supply or return air Gas 3.5 for high fire and 1.9 for low fire Temperature rise within specification range for both fire rates while the bypass damper for thr humidifier is open. Furnace operating within manufacturer's specifications at this time.