725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for new albany, oh


Map of New Albany OH
Graham M.

Graham M.


Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 new today Clean flame sensor Ohm test igniter: 62.7 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: new today #35 Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 3.2 Check amp draw on inducer motor:0.98 Check delta T - 57° Furnace is in optimal running conditions Gas heating preventative maintenance performed Check filter - 16x25x4 new today Clean flame sensor Ohm test igniter: 56.4 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - 2” pvc Set thermostat for heat Check amp draw on blower motor: 3.10 Check amp draw on inducer motor:0.23 Check delta T - 52° Furnace is in optimal running conditions