520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Local Reviews
for chadds ford, pa

Rated 5.0 out of 5 stars based on 11 customer reviews

Professional, on Time, respectful.

Barry was very professional and was aware of keeping his feet clean on his trips to his truck and back into the house. He did a thorough job with both our heating systems and gave me some pointers on thermostat settings.

  • Overall Experience
  • Quality
  • Price
  • Convenience

professionalism

great guys who knew their stuff and promptly found problem

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fine thanks.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very well

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Installers were great

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

  • Overall Experience
  • Quality
  • Price
  • Convenience

Hvac

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional and excellent service.

Kurt came to repair my heating system. He was prompt, courteous, and resolved the issue we were having with our heating/ cooling system.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

He and dave did great professional job and explained everything we asked

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fantastic job from start to finish!!!

This company added a heating and cooling system to our second floor. They were very professional and so easy to work with. They came up with a great HVAC system for our major home renovation. Their work was excellent and they tailored the stages of the job to work perfectly with the other professionals who were here working as well. Their workers are very polite and clean up meticulously. My husband and I are really pleased and impressed with the job they completed.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Prompt, courteous, and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for chadds ford, pa

Shawn R.

Shawn R. Job Checkin

Found the system had locked out because return temp was higher then supply temp. The plugs were switched from the flue temp and return temp. Also found water in the bottom of the unit upon farther inspection found a hole in the heat exchanger, used high temperature silicone to plug hole until replacement of heat exchanger or of unit is done.


Shawn R.

Shawn R. Job Checkin

Installed factory blower guard kit per recall directions. Inspected drain pan, unable to find any problems with it at this time.


Barry P.

Barry P. Job Checkin

Heat Tune Up for 5 Ton Carrier Heat pump system (basement). Washable filter ok. Measured static pressure and temperature rise. Checked defrost operation and electric heat amp draw. Cleaned EZ Trap. Checked all controls, electric motors and components. Heat Tune Up for 2.5 Ton Heat Pump System. Replaced 20x20x1 filter. Measured temp rise, static pressure. Checked refrigerant pressures/data. Defrost operation/electric heat ok. Checked all controls, wiring, electric motors and components. Both systems are operating well at the time of this maintenance.


Kurt M.

Kurt M. Job Checkin

Steam humidifier was working when we arrived, cycled the humidifier and tested operation. Checked what the solid red light on fill meant and checked the corresponding components. Water was on, electrodes and fill sensor were plugged in, went into attic and found the hose had a slight s shaped curve to it that when moved drained water back to the humidifier. Attached strapping to steam feed hose in attic to keep it from bottoming out and so that the condensate can drain back to the canister for correct operation. System was working correctly at this time.


Kurt M.

Kurt M. Job Checkin

Installed reme air purifier, also whipped out indoor air handler mold as much as possible. Re-leveled mini split with rock. Insulated condensation line in garage for furnace.


Kurt M.

Kurt M. Job Checkin

Performed precision heat tune up on all systems except (2) mini splits that are a/c only. Replaced (3) Aprilaire 213 air filters. Replaced (1) #35 humidifier pad. Provided estimates for repairs. Systems are working fine at time of inspection.


Brian B.

Brian B. Job Checkin

Performed heating maintenance, replaced air filter. Serviced humidifier, cleaned and replaced water panel. Tested electric back up heaters. Checked voltage, amperage and electrical connections, measured capacitor values. Started heat pump, tested defrost cycle and checked temperature rise across coil.


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on Goodman Gas Furnace that was replaced under warranty. Reviewed Installation with homeowner. Completed Checklist Form in system. There was not full combustion readings in the Install Checklist Form for this unit. Performed Combustion Test and Gas Pressure Test to ensure it was setup. The other Unit where the Heat Exchanger was replaced had full combustion results, so I did not perform another Combustion Test. Did note that the Unit we replaced the Heat Exchanger has Flex/Trac-Pipe connecting the Gas Line to the Gas Valve.


Brian B.

Brian B. Job Checkin

New Maintenance Plan 2021-2022 Performed heating maintenance, replaced air filter. Checked voltage, amperage and electrical connections, measured capacitor values. Tested electric back up heaters. Started heat pump, tested defrost cycle. Calculated btu output. Checked operation and temperature rise across coil


Kurt M.

Kurt M. Job Checkin

Replaced Goodman heat exchanger. Removed all other components from furnace cabinet. Installed new heat exchanger with new collector box. Made sure everything was sealed. Performed combustion test and ran furnace to burn off oils off of new heat exchanger. Also ran system in cooling mode. Pressures were 260/120 at 77 degrees. System is working fine again at time of service.


Brian B.

Brian B. Job Checkin

Checked noise in the heat mode. Cycled low fire and high fire. Checked blower speed ok. Found vent pipe rubbing duct work. Moved vent pipe away from duct. Cycled air conditioner, checked refrigerant charge and temperature drop across coil. Found no unusual noise or vibration from unit.


Luis T.

Luis T. Job Checkin

Installed new Goodman 80k furnace. Installed 6 in transition because of height difference between new furnace and coil. Installed new ez trap and wired to break R. Installed new switch and outlet. Adapted to existing gas line. Installed new propane conversion kit. Installed new intake drain kit. Adjusted propane to manufacture spec and dip switches to manufacture specs. Tested system in heating and cooling. System working properly and work area cleaned. Rest of payment for heat exchanger replacement.


Kurt M.

Kurt M. Job Checkin

Found outdoor heat pump not running. After removing the outdoor unit cover found blown 30/7.5 capacitor. Replaced capacitor and heat pump came back on. Checked refrigerant pressures, 410 a refrigerant pressures were 330/124. Checked temperature split at indoor unit, temperature split was 21 degrees. System is condensating. Heat pump system is working fine at time of service


Kurt M.

Kurt M. Job Checkin

Found that 2 other companies stated that both amana propane gas furnaces have cracked heat exchangers. Performed combustion tests on both furnaces and inspected with a camera. Found cracks in both gas furnaces. Provided quotes to replace both heat exchangers under warranty. Recommended to homeowner to replace both gas furnaces. Just replacing the heat exchangers doe not guarantee all other components will last. Homeowner will let us know if she wants us to quote installing new furnaces.


Kurt M.

Kurt M. Job Checkin

Found 24volts between c&g. Found variable speed blower motor not running. Found bad blower control and variable speed blower motor. Called distributer for price and availability. Oredered parts from distributer, will Return to complete repair.