520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.


Local Reviews
for east fallowfield township, pa

Rated 4.9 out of 5 stars based on 14 customer reviews

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Luis did another great job

Consistent, high-quality service, priced right. An active owner and a local company dedicated to customer satisfaction.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

A/C Maintenance call

  • Overall Experience
  • Quality
  • Price
  • Convenience

HVAC Tuneup

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent

  • Overall Experience
  • Quality
  • Price
  • Convenience

professional knowledgeable

Tech Paul, Arrived promptly, and was very knowledgeable. After a through inspection, trying to find the issue, he determined all my system needed was a good cleaning. I was so impressed with the amount of time he took that I signed a maintenance contract. Lastly, I should add I’m a new customer!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Follow up and Semi Annual Maintenance

Luis came out and went beyond the minimum and did additional insulation and and reconfigurations of essential elements of the system. Thank You.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

They did a great job troubleshooting for possible future problems

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for east fallowfield township, pa

Luis T.

Luis T. Job Checkin

Installed new air purifier under warranty, also replaced transformer due to malfunctioning after repairs check operation .1 amp on primary and .4 amps on secondary noticed voltage is 256 would recommended contacting peco see if there any issues with voltage coming in


Luis T.

Luis T. Job Checkin

Ductless unit condensation pump not working it won’t discharge, quoted for repairs customer ok repairs, installed new condensation pump 115 volt, check drain by pouring water inside evaporator pan draining ok test pump ok, cleaned filters and also add tabs to coil pan check operation of unit supply air 54 return air 73


Kurt M.

Kurt M. Job Checkin

Found when I arrived outdoor fan motor running but not compressor. Tested 35/5 mfd capacitor, capacitor tested at 34.7/5 mfd. also found contacter buzzing. Told homeowner the only option we can try is to put a hard start on the system to see if we can temporarily get compressor to work. After putting on spp6 hard start, older ducane a/c came on. System ismiss matted with a newer carrier air handler in the attic. Recommend replacing the system, homeowner would also like to get a price if he were to replace both first and second floor systems. R-22 pressures are 239/60. System is cooling for now,


Luis T.

Luis T. Job Checkin

Perform AC tuneup check electrical low and high voltage connections checked blower ECM motor replaced air filter check supply and return temperature clean condensate pump test pump and add tabs to the pump check outdoor unit refrigerant pressures r22 capacitor contactor, amp draw and voltage ok noticed reme air purifier not working we need to come back to replace reme


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, replaced air filter. Cleaned condensate drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Barry P.

Barry P. Job Checkin

Smell caused by build up on condensate pump. Checked evaporator. Cleaned and added condensate tablets to evaporator. Cleaned condensate pump. Checked collector box and tubing for smells)trapped water; ok. Issue resolved.


Kurt M.

Kurt M. Job Checkin

Performed precision a/c Tune up on Lennox a/c system. Replaced 16x25x1 air filter. Checked all electrical conections and components. Found thermostat buttons are failing, emailed customer some WiFi thermostat replacement options. Checked temperature split at indoor unit. Blew out condensate drain. Checked refrigerant pressures and temperatures at indoor and outdoor units. A/c system is getting older but is working at time of inspection.


Luis T.

Luis T. Job Checkin

Performed ac tune up check electrical low and high ok replaced air filter, flushed drain ok check temp split supply and return ok cycle unit check outdoor unit refrigerant pressures capacitor and contactor ok cycle outdoor unit ok system is working within manufacturers specifications,


Barry P.

Barry P. Job Checkin

Six month inspection for 100,000 BTU 2 stage Amana furnace and AC system. Heating temp rise 45F. Cooling temp split 17F. Cleaned EZ trap verified drain. Cleaned flame sensor. Visual inspection of burners and heat exchanger ok. Combustion test good. Compressor amps/outdoor voltage/outdoor capacitor ok. Both heating and cooling system are operating well at the time of this 6 month inspection.


Barry P.

Barry P. Job Checkin

AC Tune up for 5 ton American a Standard AC system. Cleaned drain, EZ trap and verified condensate pump operation. 24F temp split with outdoor air 68F. Replaced filter. Both coils are in good condition. Refrigerant pressures/subcooling/superheat ok. Outdoor voltage/compressor amps ok. System is operating well at the time of this maintenance/ tune up.


Luis T.

Luis T. Job Checkin

No heat, found seized inducer motor, check availability from manufacture, also quoted for repairs customer ok repairs, we will be returning tomorrow to install inducer assembly, during today’s visit performed A/C tune up check electrical low and high voltage Connections ok, replaced air filter, cleaned condensation pump test pump ok check supply and return temperature, ok check outdoor unit refrigerant pressures capacitor ok cleaned outdoor coil with water cycle unit ok 4-1-21 Return visit to install inducer assembly after repairs performed combustion test on propane furnace, (part under manufacture part warranty)


Kurt M.

Kurt M. Job Checkin

Performed precision a/c tune up on Goodman a/c system. Replaced 16x20x1 air filter. Checked all electrical conections and components. Found weak 35/5 440v duel capacitor. Replaced. Blew out condensate drain. Checked temperature split. Checked refrigerant pressures and temperatures at indoor and outdoor units. A/c system is working fine at time of inspection.


Joseph D.

Joseph D. Job Checkin

Installation of Reme Air Scrubber, Put in a steep down transformer to power up reme air purifier,


Barry P.

Barry P. Job Checkin

When the inducer motor was slightly out of place. Reset and cycled furnace several times to verify.


Kurt M.

Kurt M. Job Checkin

Performed precision heat tune up on trane gas furnace. 16x25x1 air filter is clean. Checked all electrical conections and components. Found inducer motor bearings are very noisy, also inducer motor amp draw is high. Recommend replacing inducer motor. Cleaned flame sensor. Blew out condensate drain and tested condensation pump. Checked temperature rise. Checked gas pressure and performed combustion test. Gas furnace is working at time of inspection. 1/28/21. Installed new inducer motor on trane gas furnace. Tested operation of furnace and took combustion readings. Also installed 50 gallon Bradford water heater. Adapted to exsisting piping with 3/4” copper and new expansion tank set in drain pan on bricks with water alarm. Checked gas line for leaks. Tested water pressure and temperature at faucet. Both furnace and water heater are working fine at time of service.