Chris B.

Chris B. Job Checkin

Performed QA on Goodman Air Handler and AC installation. Reviewed installation with homeowner. Tested system in heating mode and took temperature splits. Tested the EZ trap safety and tested the condensation pump. Completed checklist form in system. Corrected any issues that were found during visit. *This is an install we should go back for the Six Month Inspection once it’s warmer outside to verify the refrigerant charge. Lineset is longer and runs through the crawl space.*


Chris B.

Chris B. Job Checkin

Performed QA on Trane Gas Furnace/AC system. Upon arrival homeowner informed me that the system was blowing the fuse and also the drain line had clogged several times. Checked over all wiring on system. Began testing wiring but did not have enough fuses and did not have the Fuse Popper Tool. After Kurt arrived was able to find that the thermostat was bad. We installed the T4 during the install but after we left they reinstalled there own thermostat. Installed the T4 thermostat and programmed. Put system into operation and tested in heating and cooling. Performed combustion testing and tested the vent motor pressure switch safety. Blew through the condensate line and poured several bottles of water through the drain to make sure it was draining. Reviewed thermostat operation with the tenant. Completed checklist form in system.


Joseph D.

Joseph D. Job Checkin

Completed estimate for new Trane furnace and ac for rental property. Emailed to customer.


Kurt M.

Kurt M. Job Checkin

Performed precision oil tune up on Weil McLain oil boiler. Replaced rf1 oil filter. Checked all electrical conections and components. Replaced.75x70b nozzle. Vacuumed soot from heat exchanger and smoke pipe. Performed smoke and combustion test. Oil boiler is working fine at time of service.


Kurt M.

Kurt M. Job Checkin

Found defective expansion tank/ should replace relief vaule could have issues in near further if not replace now:also offer gas boiler tune plan to save on repaired.


Luis T.

Luis T. Job Checkin

Found recently install damper not connected on Honeywell panel


Kurt M.

Kurt M. Job Checkin

Perform 6 month inspection on 2 recently installed amana gas furnace. Replaced one 16x24x1 filter. Check temperature rise on furnace and performed combustion test. Also installed new damper for 3rd floor. Both systems working great at 6 month inspection.


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on Amana AC/Coil Installation. Reviewed installation with homeowner. Completed Checklist form in system. Replaced the 20x25x1 Air Filter which was very dirty. This install passed the QA Inspection: Indoor and outdoor unit looked nice. AC was level, wiring was clean and secure, everything was sealed. Only note is to remind the Installers to check the Air Filters on systems. The Air Filter was very dirty and should have been replaced. Overall, the guys did a nice job.


David B.

David B. Job Checkin

Reclaimed and removed old ac and coil. Installed a new ADP coil on top of existing furnace and taped. copper lines brAzed and leak checked with nitro and bubbles. Ran new vinyl to discharge pipe. New condensate drain with an ez trap and pump wire into system. Made a supply plenum and taped all possible air leaks. Tested unit in ac and checked for condensate leaks tested condensate pump and collected balance.


Brian B.

Brian B. Job Checkin

Checked no cooling complaint, checked air filter ok. Blower is running. Checked outdoor unit. Found open run capacitor. Replaced run capacitor. Started air conditioner, found compressor running at 72 amps and is grinding from inside the compressor. Cycled off and compressor will not start again. Recommend replacing air conditioner.


Kurt M.

Kurt M. Job Checkin

Performed quality assurance inspection on both first and second floor systems amana gas furnace and a/c systems. (1) of the zone dampers in attic area is temporarily always open to provide air to that zone. Also need to bring a switch cover when we return for second floor system switch box. Both systems are working fine at time of quality assurance inspection. Homeowner would like the damper replaced as soon as possible.


Paul W.

Paul W. Job Checkin

Reclaimed and removed old equipment. Installed new leveled pad, disconnect, whip, and Amana condenser. Flushed lineset. Brazed in line set with nitrogen. Connected high volt and low volt connections and sealed holes. Installed new Amana gas furnace and evaporator coil and brazed in line set with nitrogen. Pressure tested to 300 and evacuated down to 115 microns. Reconnected return , plenum, and sealed all connections. Installed new switch and receptacle and wired in high volt. Installed new ez trap and condensate pump and wired safety’s to break r. Reconnected gas line and leak checked. Installed new vinyl to discharge. Reconnected venting. Tested system in heat and adjusted gas pressures and performed combustion test. Tested system in cool and adjusted refrigerant charge. Tested condensate pump. System working great at time of install. Reclaimed and removed old equipment.relocated existing zone dampers to attic. Installed new leveled pad, disconnect, whip, and Amana condenser. Fl


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on system. Reviewed installation with homeowner. Checked operation of system. Replaced 14x25x1 Air Filter. Checked refrigerant charge and added 8 oz of refrigerant. Tested safety devices and cycled system. Homeowner said that one time the system was set to cooling but it did not come on. Checked system and found no issues at this time. Need to email customer the T6 Wifi Thermostat operating manual.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance on second floor air conditioner, replaced air filter. Checked condensate drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge, found unit low on charge. Recommend replacing system due to age and R22 refrigerant. Dan wants to wait and see how it does.


Brian B.

Brian B. Job Checkin

Checked no heat complaint, found room temperature at 73, turned furnace on, furnace instantly started and ran, checked air filter new, checked blower and run capacitor ok. Checked flame sensor it’s an obsolete mercury sensor and spark ignition. Cleaned pilot burner and sensor. Cycled furnace can not get furnace to fail. Recommend replacing furnace and air conditioner, system is 45 years old and parts are becoming obsolete and furnace will not be repairable.