Joseph D.

Joseph D. Job Checkin

Spoke with Bob on arrival who indicated unit was not keeping up consistently on hot days and temperature would climb during the day until is was up in the 80s. Walked the home, the unit installed is for the 2nd floor only. Reviewed installation and inspected ductwork for leakage. Old ducts are not sealed, it is recommended to seal ductwork but this is not related to problem. Inspected wiring and found unit wired as 2 stage and outdoor unit is a single stage unit. Rewired to jump Y1 and Y2 together as recommended in installation manual. Checked dipswitches to ensure airflow is setup properly, set to 390 cfm/ton and set to 2 ton. There was no signs of condensation in pan or around drain line but trap is not insulated. Turned system on and checked system charge and delta across coil. Superheat at 18 degf and subcooling at 8 degf and delta T at 18 degf. System is working properly at this time. It was 75 degf outside so there were no signs of a problem. Instructed Bob to call me


Joseph D.

Joseph D. Job Checkin

Reviewed jobsite and discussed projects regarding attic insulation, ventilation, and conditioning. Also, looked at releveling outdoor Trane unit and servicing Trane system.


Tony F.

Tony F. Job Checkin

Estimate


Tony F.

Tony F. Job Checkin

Estimate


Chris B.

Chris B. Job Checkin

Performed QA on Goodman Air Handler and AC installation. Reviewed installation with homeowner. Tested system in heating mode and took temperature splits. Tested the EZ trap safety and tested the condensation pump. Completed checklist form in system. Corrected any issues that were found during visit. *This is an install we should go back for the Six Month Inspection once it’s warmer outside to verify the refrigerant charge. Lineset is longer and runs through the crawl space.*


Chris B.

Chris B. Job Checkin

Performed QA on Trane Gas Furnace/AC system. Upon arrival homeowner informed me that the system was blowing the fuse and also the drain line had clogged several times. Checked over all wiring on system. Began testing wiring but did not have enough fuses and did not have the Fuse Popper Tool. After Kurt arrived was able to find that the thermostat was bad. We installed the T4 during the install but after we left they reinstalled there own thermostat. Installed the T4 thermostat and programmed. Put system into operation and tested in heating and cooling. Performed combustion testing and tested the vent motor pressure switch safety. Blew through the condensate line and poured several bottles of water through the drain to make sure it was draining. Reviewed thermostat operation with the tenant. Completed checklist form in system.


Joseph D.

Joseph D. Job Checkin

Completed estimate for new Trane furnace and ac for rental property. Emailed to customer.


Kurt M.

Kurt M. Job Checkin

Performed precision oil tune up on Weil McLain oil boiler. Replaced rf1 oil filter. Checked all electrical conections and components. Replaced.75x70b nozzle. Vacuumed soot from heat exchanger and smoke pipe. Performed smoke and combustion test. Oil boiler is working fine at time of service.


Kurt M.

Kurt M. Job Checkin

Found defective expansion tank/ should replace relief vaule could have issues in near further if not replace now:also offer gas boiler tune plan to save on repaired.


Luis T.

Luis T. Job Checkin

Found recently install damper not connected on Honeywell panel


Kurt M.

Kurt M. Job Checkin

Perform 6 month inspection on 2 recently installed amana gas furnace. Replaced one 16x24x1 filter. Check temperature rise on furnace and performed combustion test. Also installed new damper for 3rd floor. Both systems working great at 6 month inspection.


Chris B.

Chris B. Job Checkin

Performed Quality Assurance on Amana AC/Coil Installation. Reviewed installation with homeowner. Completed Checklist form in system. Replaced the 20x25x1 Air Filter which was very dirty. This install passed the QA Inspection: Indoor and outdoor unit looked nice. AC was level, wiring was clean and secure, everything was sealed. Only note is to remind the Installers to check the Air Filters on systems. The Air Filter was very dirty and should have been replaced. Overall, the guys did a nice job.


David B.

David B. Job Checkin

Reclaimed and removed old ac and coil. Installed a new ADP coil on top of existing furnace and taped. copper lines brAzed and leak checked with nitro and bubbles. Ran new vinyl to discharge pipe. New condensate drain with an ez trap and pump wire into system. Made a supply plenum and taped all possible air leaks. Tested unit in ac and checked for condensate leaks tested condensate pump and collected balance.


Brian B.

Brian B. Job Checkin

Checked no cooling complaint, checked air filter ok. Blower is running. Checked outdoor unit. Found open run capacitor. Replaced run capacitor. Started air conditioner, found compressor running at 72 amps and is grinding from inside the compressor. Cycled off and compressor will not start again. Recommend replacing air conditioner.


Kurt M.

Kurt M. Job Checkin

Performed quality assurance inspection on both first and second floor systems amana gas furnace and a/c systems. (1) of the zone dampers in attic area is temporarily always open to provide air to that zone. Also need to bring a switch cover when we return for second floor system switch box. Both systems are working fine at time of quality assurance inspection. Homeowner would like the damper replaced as soon as possible.