Performed QA on Trane Gas Furnace/AC system. Upon arrival homeowner informed me that the system was blowing the fuse and also the drain line had clogged several times. Checked over all wiring on system. Began testing wiring but did not have enough fuses and did not have the Fuse Popper Tool. After Kurt arrived was able to find that the thermostat was bad. We installed the T4 during the install but after we left they reinstalled there own thermostat. Installed the T4 thermostat and programmed. Put system into operation and tested in heating and cooling. Performed combustion testing and tested the vent motor pressure switch safety. Blew through the condensate line and poured several bottles of water through the drain to make sure it was draining. Reviewed thermostat operation with the tenant. Completed checklist form in system.