Arrived to do ac maintenance on both systems. First floor: Went ahead and checked thermostat for operation, changed filter, checked temperature split, checked blower motor amp draw and run capacitor, checked compressor amp draw, condenser fan motor amp draw, checked dual capacitor, checked refrigerant pressures, system is working correctly at this time. Second floor: Went ahead and checked thermostat for operation, changed filter, cleaned and primed ez trap, checked temperature split, checked blower motor amp draw and run capacitor, checked compressor amp draw, condenser fan motor amp draw, checked dual capacitor, checked refrigerant pressures, system is working correctly at this time. Checked incoming water pressure found it to be at 60psi went over options to increase amount of hot water accessible in home as well as filtration options.