2005 water furnace premier, pressurized closed loop system Upon arrival the system was working in good condition in cooling mode with a regular work order for general seasonal maintenance Initial inspections and minor maintenance cleaning in the electrical compartment discovered loose high voltage wiring arcing multiple times during the inspection. While searching for the cause of the electrical noise the integrity of the water furnace premier control board was compromised and the system shut down and would not reinitialize the compressor operation Install replacement water furnace premier control board from service stock Complete all the general duties of the maintenance including drain flush, minor maintenance air dusting and cleaning, filter rotation provided by homeowners, ground loop pressure testing, cooling mode operation testing Considering the age the equipment is running in very good condition All wiring in the electrical compartment has been inspected and secured. The