403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for columbia, md


Map of Columbia MD
dennis@haasandsons.com

dennis@haasandsons.com


Job Checkin

Installation of new two-pole breakers to replace current broken breaker for the bedrooms on the second floor. Installation of two new switches in both bedrooms on the second floor (primary and kids room). During our visit we addressed the many concerns with the main 200 amp panel. I saw during our visit many concerns such as over heating circuits, shared breakers, double taps, rust and no whole home surge protection. I also noted with the inspection on the hardwired smoke and carbon detectors being outdated and not interconnected. I highly recommended on replacement of the main panel as well as updating the safety concerns with the home as time goes on from last visit, things were getting worse with the panel. After providing solutions, we went over the options and customer would like to take time to go over the options and reach back out when ready to schedule.