Listened to and responded to plan. Offered good insight and suggestions.
Michael called when he was on his way. He completed the job. He was very professional throughout the whole process. Would recommend Michael and the Haas company.
Alex was the technician on the job. He was positive, personable and professional. He quickly provided an estimate on the work and gave me some options for adding recessed lighting to a closet ( even though I chose not to do it). He was very knowledgeable and explained all the work. He did an excellent job !! I would give him 5 stars !!!
Excellent work. Good review of work & products prior to doing the work. Alex is an e excellent worker. Keeps on the job and cleans up after.
Alex did a great job ! He was friendly and personable. He explained the work that was needed, and provided me an estimate of the work within minutes. He completed the work in no time at all and did a thorough job. In addition, he provided recommendations to improve the electrical system throughout the house.
Nick was personable and knowledgeable. I’m grateful for the same-day service call that fixed three different electrical problems.
This solution includes the installation of 4 new customer supplied pendant lights in the kitchen area. In addition we shall properly terminate new switches in the 4 gang box. Lastly this includes 2 dimmer switches for recess and pendant fixtures. We have installed the new customer supplied lights in the kitchen. Additionally we have replaced the existing 4 switches in the 4gang box, terminating them properly and have installed 2 new dimmers to operate the recess lights and the Pendant lights.
This solution includes the installation of a customer supplied switch and receptacle upstairs. We have installed the customer supplied devices in the upstairs. We recommend replacing the furnace wiring.
We have delivered pricing regarding the installations.
This solution includes the installation of a new dedicated 240V 40A circuit and receptacle for EV charging purposes. New receptacle shall have gfci protection. We have installed the 40A dedicated circuit.
We removed the old doorbell and replaced it with a blank plate. Customer was interested in adding a receptacle by basement utility closet, underneath the stairs. Gave a quote for said work. Customer will speak with husband and will call office if interested in going forward with work.
The reason for today’s visit was to provide solution for a EV charger install. Customer had purchased an EV charger already but, when shown the difference between hardwired and plug in models she would prefer the hardwired version and will be returning what she purchased. As we began at the panel, i saw a 97 Cutler Hammer CH panel with no surge but proper grounding and bonding. Each neutral was under the own terminal on the ground bar and i saw no signs of issues with the branch circuits. The customer did however have Solar installed and had a passing permit labeled on the panel from 2017-19 timeline. After discussing the options for today’s visit, a solution was provided for running a new 60 amp circuit by way of directional boring. We would run #6 THHN wire through 3/4 inch conduit from the panel room (in basement) through the front yard and under the flower bed having stubbed the wires on the exterior of the garage. We would then drill through the brick on the garage to land a junct
Installation of new coach light o the exterior of the home. Current light fixture is damaged and no longer works.
Replace customer supplied intercom station
Install new 200 amp electrical panel, breakers, bring grounding up to current code, pull electrical permit, schedule inspections with county/ pepco
This solution includes the installation of a new customer supplied vanity light in the first floor bathroom. We have installed the new bathroom vanity light on the first floor.
I removed and replaced a light for the customer on back deck. Customer supplied I also re-installed a customers smoke alarm on third floor NO warranty
Today’s visit was for dedicated circuit to new pool pump. During assessment, I saw the CH panel, even though clean, was at full capacity. To make room for a dedicated circuit, please see solutions to get this resolved for you.
We will replace the existing 200 amp panel with a new 42 space panel with all new matching breakers. We will install new service cable to replace the deteriorating existing cable from the panel to the meter as well as from the meter can to the new mast. We were installing new service mast through the roof to raise the cable up off of the house We will install new grounding system which includes main water grounding, as well as ground rods on the outside of them. We will accurately label panel and check once completed. We will pull an electrical permit and coordinate county inspections, as well as power company tie in. We will pull dedicated circuit to the microwave, as well as install a new dedicated circuit with a receptacle in the front portion of the Home.
Customer wanted six additional recessed can lights installed in living room on top floor. While doing my assessment before beginning the work, I saw that the panel was a Bryant panel original to the home in 1979. I strongly recommend getting this replaced as soon as possible. Please see attached solutions to get that resolved for you. Work performed today: Install (6) customer supplied recessed lights