203 North Main Street
Mount Gilead, NC 27306
910-439-9598

Job Locations
for asheboro, nc


Map of Asheboro NC
Becky L.

Becky L.


Job Checkin

Pride Plumbing came out and replaced a leaking 50-gallon electric water heater with a new 50-gallon electric A.O. Smith ENS-50 110 model. First, after disconnecting its electrical connections and inlet and outlet water lines, we removed and disposed of the old water heater. Then we installed a water heater pan, the new water heater, a thermal expansion tank, ball water shut-off valves, PEX and stainless-steel water supply lines to the water heater connectors, a brass drain valve, and wired up the electrical connections to the new water heater (adding a Romex connector). Finally, we bled the air out of the water lines, ensured that the unit’s temperature and pressure (T&P) relief valve was properly vented, and set the unit to its appropriate operating temperature. We also provided a cost estimate to trench a ditch from the water meter to the home and replace the black roll main outside water supply line and pressure reducing valve (PRV) at the water meter.

Pride Plumbing came out and replaced a leaking 50-gallon electric water heater with a new 50-gallon electric A.O. Smith ENS-50 110 model. First, after disconnecting its electrical connections and inlet and outlet water lines, we removed and disposed of the old water heater. Then we installed a water heater pan, the new water heater, a thermal expansion tank, ball water shut-off valves, PEX and stainless-steel water supply lines to the water heater connectors, a brass drain valve, and wired up the electrical connections to the new water heater (adding a Romex connector). Finally, we bled the air out of the water lines, ensured that the unit’s temperature and pressure (T&P) relief valve was properly vented, and set the unit to its appropriate operating temperature. We also provided a cost estimate to trench a ditch from the water meter to the home and replace the black roll main outside water supply line and pressure reducing valve (PRV) at the water meter. Pride Plumbing came out and replaced a leaking 50-gallon electric water heater with a new 50-gallon electric A.O. Smith ENS-50 110 model. First, after disconnecting its electrical connections and inlet and outlet water lines, we removed and disposed of the old water heater. Then we installed a water heater pan, the new water heater, a thermal expansion tank, ball water shut-off valves, PEX and stainless-steel water supply lines to the water heater connectors, a brass drain valve, and wired up the electrical connections to the new water heater (adding a Romex connector). Finally, we bled the air out of the water lines, ensured that the unit’s temperature and pressure (T&P) relief valve was properly vented, and set the unit to its appropriate operating temperature. We also provided a cost estimate to trench a ditch from the water meter to the home and replace the black roll main outside water supply line and pressure reducing valve (PRV) at the water meter.