Pride Plumbing was called out for a toilet tank that would run constantly and not fill. Our inspection found that the toilet tank's flapper was deteriorated and would not seal off the tank which caused it to run constantly. We replaced the toilet tank's flapper with a new 3-inch red universal model and tested for leaks and proper operation with no issues. We also made an adjustment to the tank's water fill valve. We provided a cost estimate to replace the toilet with a new Gerber Viper model. This would include draining and pulling the old toilet, inspecting/cleaning/replacing the flange, replacing the toilet bowl, toilet tank, flapper, water fill valve, tank to bowl gasket and bolts, seat, wax ring gasket, toilet bowl bolts, toilet bowl bolt washers, toilet bowl bolt caps, and above-floor stainless steel braided water supply line.