Job Checkin

Arrived on site to perform AC diagnostic on 1997 York condensing unit. Upon arrival Richard stated that system was fix five years ago and he believed that the compressor was replaced. Now he states that it just blows warm air in the house. Began diagnostic and immediately found the compressor was not on. Duel secondary motor control checked out properly and starter looked OK. Found that compressor start wire was completely melted off of terminal connecting to compressor. Due to the severity of the Burnt terminal I was unable to reconnect with a new female fitting due to the pin connector being deformed from high amps. System has severe oxidization due to it being close to Ocean. Ultimately pin connector are damaged on compressor, this would have to be swapped out. R22 is no longer manufactured as of 2020 and will result in this becoming a very expensive repair for 1997 system. At this time Richard will be going on a trip to Europe for three weeks and will not be using the system so rec