520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for aston, pa


Map of Aston PA
Luis T.

Luis T.


Job Checkin

Removed old oil heater and AC, as well as the hot water heater, Installed new 80% natural gas heat/AC Also installed 35 feet of 1 inch galvanized pipe with hangers supporting piping to exterior wall pressure tested in line outside to six psi, gas piping held pressure for 24 hours, installed gas manifold inside the heater room with three ports, one for the water heater, one for the gas heater, and left them one spare for the future appliances. Install gas valves at manifold and add water heater and new furnace Ripped out Old return drop and install new 25 x 10 return boot and one length of 25 x 10 return duct, also added one return to the basement level.Wired in safeties by breaking or terminal on furnace board tested condensate pump and easy trap switch all or operational seal all duck work with tape and silicone no leakage at time of completion. Waste isolation pads under condensate pump and ran new vinyl tubing to slop sink in side. Tested gas pressures and did combustion check