Perform tuneup on two AC systems. Inspected indoor and outdoor coils, flushed drain lines, replaced air filters, inspected blower wheels, checked temperatures, checked static pressure, checked refrigerant pressures, inspected all major and minor electrical components. Both systems need to have UV bulbs replaced, surge protectors need to be installed, both systems have high compressor startup amps, first floor system has a weak capacitor, and is low on refrigerant. Gave client solutions for issues with system. Client needs to discuss with spouse and will get back to us. Cycled the and tested both systems, all operations OK at this Time.