Justin did fantastic and fast work on our ac. He even arrived early! Justin is always very kind and professional!
Checked operations of both systems, coils, amps, wiring, capacitors all good, cleaned drains lines and condensation pump, washed out condensers, talked to customer about hole in the closet which he will be getting repaired. Both systems running well at this time
Preformed maintenance on both systems, installed floats as requested. Both systems in good condition, cabinets are clean, uv lights are good. Found no burnt wires or loose connections, amps, charge, coils are all good, cleaned out condensers, vacuum pumped both drain lines, both systems are good to go!
Cleaned drain line. Cleaned coils. Checked freon pressures. Tstat was reaching desired temperature.
Found system running low on refrigerant not able to keep up. Upon leak detection could not pinpoint leak to inside or outside. Recommend replacing for 10 year warranty coverage and higher efficiency.
Cleaned drain line. Float switch was tripped
Client said system was having issues cooling. After doing a full diagnostic including checking refrigerant pressures and temperatures, condensate line, all major and minor electrical components, and supply and return temperatures there were no issues discovered. System is running optimally, however It is recommended to add surge protectors to both outdoor units.
Brennan G Today I visited for the system not cooling or heating. We discovered the compressor fan capacitor had failed. We replaced the faulty component and installed a compressor start assist. The system is now operational. We enrolled the system into our maintenance agreement and i install a client supplied thermostat. I plan to return this week with the correct size capacitor and preform the first maintenance visit.
Task Includes -Installation of 15 SEER2 4 Ton Carrier Heat Pump System -Relocating air handler to garage -New insulated large stand -New supply and return plenums -Demo electrical sub box in existing air handler closet -New electrical for air handler -New electrical line for condenser. -Running new drain line for new air handler location. -Replacement of 9 supply air lines and adding 1 supply air in future -10 year parts 1 year labor warranty -All permits and inspections included
Upon arrival Shawn stated system was going out on high pressure lock out. Investigated system to find head pressure too high for conditions outside. Removed charge until head pressure was in my option resonable for conditions outside. Advised that when we return to do inspection before summer we reevaluate charge due to proper charging should be done in ac mode. All is now heating home as designed
Sold new 4 ton carrier 15 SEER2 Heat pump Will be moving system into garage on large insulated stand Will be replacing all duct work and leaving boot boxes One duct run will not be connected or ran until new room is built Will be adding new 20x20 return Electrical will be ran by green light Client will be calling in the next couple days to pay deposit by cc
Brennan G Today I visited to preform maintenance on the trane central system and the daikin mini split. Both systems are clean and all electrical components are within specs. I sprayed the evaporator coils with non rinse cleaner and cleaned the minisplit filters. Both systems are operating normally at this time. The filters for the trane system are 18x20x1
Brennan G Today I visited and preformed maintenance on both systems. I also added remaining charge into the downstairs system. All the equipment is working properly at this time. I verified the coils are clean and I cleaned both Ptraps. I verified the electrical components are within specs.
10 year parts warranty 1 year Labor warranty 1st year maintenance Permits and inspections Warranty registration Removal and disposal of old equipment and materials All labor and taxes Drain line flush Float switches New thermostat digital New refrigerant lines 3/8 and 3/4 Electric heater kit Supply plenum connection New hurricane pad and tie downs
Brennan G Today I visited for a system replacement estimate. Kelly and Bill elected to have us install a new system. The work is scheduled for today.
Uninstalled existing evaporator coil and reinstalled a new replacement evaporator coil. Added 15lbs of 410a freon.