8999 66th Ct Unit 102
Pinellas Park, FL 33781
727-433-9853

Local Reviews
for wimauma, fl

Rated 5.0 out of 5 stars based on 2 customer reviews

Again, excellent service. Tech was professional and expedient!

All technicians from Mason have been highly skilled and effective. Will use Mason again for AC service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service?

Timely, expert service! True professional. Fixed the problem others could not fix

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wimauma, fl

Aaron K.

Aaron K. Job Checkin

Gave client options on duct repair and duct cleaning. Client needs to review estimate with spouse and get back to to us.


Shawn H.

Shawn H. Job Checkin

Provided estimates to install client provided mini split.


Shawn H.

Shawn H. Job Checkin

Condenser does not start when called. Found hermetic starter failed. Provided estimate for part replacement as well as enrollment in maintenance program and, at client request, duct cleaning. Client chose to proceed with repair and maintenance plan. All services completed on site. Balance collected via cc.


Kevin@masonairconditioning.com

Kevin@masonairconditioning.com Job Checkin

Task Includes -Pumping system down -Replacement of in warranty evaporator coil -Installation of new inline filter dryer -Pressure testing system -Pulling required vacuum on system -Freon Per LB -Maintenance Plan with discount


renfroejames00@gmail.com

renfroejames00@gmail.com Job Checkin

Arrived to find system not cooling well. Found system low on r410a Found leak in evaporator coil Gave client estimates and invested in maint plan and repairs Client goes out of town tomorrow and won’t return until Monday the 23rd. Need to schedule when returns Today’s task Includes -Adding correct charge to system for peak performance -No additional charge once main repairs are made in system


Justin@masonairconditioning.com

Justin@masonairconditioning.com Job Checkin

Need to return to replace in warranty condenser coil All under first year warranty.


Hunter B.

Hunter B. Job Checkin

Came out from machine leaking water upon arrival found no water in the drain line and no clog. Machine is covered in growth. One of the words that I’ve seen the growth on the bottom of the coil is causing the machine drip water out the front of the pan recommended customer gets a professional Inspection guy to come in because it looks severe and the machine is not too old also because they have kids in the house and I don’t wanna do a temp, fix and cause more launch problems


GFunkzx6r@gmail.com

GFunkzx6r@gmail.com Job Checkin

Built new return plenum and changed up bulb


Aaron K.

Aaron K. Job Checkin

Mach one system maintenance performed and system is now operating normally. Condensate line was found to have an ascending pitch, not allowing proper draining and causing float switch to trip periodically. This caused the return plenum to become saturated with water. Customer was informed of this and paid for reconstruction of condensate line, allowing proper draining. Customer was advised and agreed to replace return plenum as well (to be completed 4/24/25). Condensate line flushed, air temperatures were recorded and are good static pressures are good, refrigerant pressure and temperatures were checked and are good, all major and minor electrical components were checked. Compressor did have excess inrush amps upon startup, customer was advised of this and opted for a hard start kit per recommendation. Customers was informed their preexisting uv bulb was burnt out and agreed to replacing it per recommendation. Bulb has been ordered and will be installed with new return plenum.


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Returned and investigated further into system about breaker tripping. Found no indications of a reason for system to trip the breaker. Asked further questions to then discover that the outdoor unit would randomly turn off then client would have to reset the breakers by turning off then back on to reset system. Checked Freon pressures to find extremely low on r-410a. Found leak in condenser coil. Need to order jew condenser coil under. 1 st year warranty. Charged system to get client by.


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Arrived to find system working. Mr melrose stated system would trip breaker he would reset would run sometimes for 2 hrs and then sometimes 3. System had been running for roughly 12 hrs when I arrived inspected all high voltage wiring to system and when I touched breaker feeding condenser it was extremely hot to the touch. Ran to ace and grabbed another breaker system now operating as designed


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Brennan G Today I returned and reolaced the circuit breaker. I tested the system to make sure it is operating normally. Please mail a receipt


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Brennan G Returning tomorrow to replace breaker


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Brennan G Today I visited for a system maintenance. I cleaned the air filters, washed the condenser coil. I verified the refrigerant levels are good and the drain lines are clean We enrolled the system into our maintenance agreement.


Info@masonairconditioning.com

Info@masonairconditioning.com Job Checkin

Client showed me control wire from generator and I called installation company who installed it and they stated the wire does not need to be connected and to just disconnected it inside the transfer box which I did