- install secondary24 V UV light underneath evaporator coil - relocate existing UV light - Pull and clean evaporator coil - Pull and clean blower wheel - install hard start assist - additional 10% discount on top of the membership discount Relocated and replaced UV bulb in existing UV light, pulled and cleaned evaporator coil and blower wheel, pulled vacuum on system and recharged with refrigerant, installed secondary UV light underneath evaporator coil, installed hard start kit in condenser. Cycled and tested system, all operations OK at this time.