Low volt really bad outside Cap on way out, condenser comes on sometimes, when i arrived was was working Needed to remove schedule on the thermostat Reprogram thermostat Replace cap Low volt outside fix James friend, is not available at the moment due to meetings, send link for payment please No email on file James returned for lack of air flow Found flat roof home with no access to duct work and spare bedrooms, kitchen, and living room with lack of flow. Found blower speed tap on low. Increased to high speed to gain more flow and advised client to purchase new high flow grills for kitchen area to gain better control of air movement from vent the kitchen has a 3 way grill and is forcing air to ceiling. Relocated condensate pump for access to filter due to return air filter only has a piece of flex laying behind it and is actually too small for the size system it has in it. There is no safety’s for water over flow as well. Hopefully these adjustments will improve the air in home