Job Checkin

Install new 3/4 PVC drain line from condensate pump to exterior of building. Line is approximately 15' in length. Line will use existing unused portal to exterior of building or new portal created with hole saw. 3/8 rubber line will be used to connect condensate pump to 3/4 PVC line, with appropriate barbed fittings and hose clamps. ----- Condensate System Repair Materials: - 20ft 3/4 PVC - 3ft Rubber tubing for existing pump - Clamps to secure tubing to pump and line - 3/4 PVC trap, fittings - Tall A-Frame ladder - Drill with bit to send 3/8 line outside - Replacement secondary pan (may not need, judge if can be repaired) - 1/2 sheet Ductboard with mastic and tape to transition supply, if needed Scope: - Lift air handler -6in to accommodate proper drain to pump, ensure level - Secure existing pump inside secondary pan with vent and trap to allow drainage - Transistion plenum if necessary, resecure and seal to code - Run new PVC line to exterior of building, connect to pump with