725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for delaware, oh


Map of Delaware OH
Graham M.

Graham M.


Job Checkin

11/5/25 7:00pm Emergency service – upon arrival inspected furnace and found leaking by gas valve. Homeowner was interested in instant replacement. Remove and replace valve with available parts on van adjusted price accordingly for a warranty valve under after hours labor. Homeowner informed me of a technician previously adjusting airflow on the furnace downstairs, giving him more problems than solution. He wanted me to convert it back. I believe I have converted it back to the original settings. It was on. I changed orange to gray. If things aren’t better next season, we will further address. Back in 2023 homeowner previously requested Brandon to quote ERV addition for attic, his original request was denied due to unavailability new request is being sent in to office and we will update with information when we have it. Gas heating preventative maintenance performed Check filter - 20x25x4 filter due by December. Clean flame sensor Ohm test igniter: 54.3 Inspect wiring for loose con