725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for dublin, oh


Map of Dublin OH
Brandon P.

Brandon P.


Job Checkin

2024 Daikin high efficiency gas furnace running in new condition. Aprilaire 210 air filter is new today. Clean flame sensor and check ignitor. Visual inspection of burners. Flush condensation trap and drain lines. Humidifier damper is open, pad is in good condition, and humidity is set to 40%. Test ran furnace in gas heating mode from thermostat. System is operating properly within temperature rise specifications. Manifold gas pressures are set properly. Blower motor and inducer motor are operating within specifications. 2" pvc flue vents are in good condition and no sign of leaks. 0PPM CO detected during testing. System is operating properly, efficiently and ready for Winter.