725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for galena, oh


Map of Galena OH
Jason D.

Jason D.


Job Checkin

Install Daikin Aurora Ductless System *Variable Speed Heat Pump: Model #: RXT15AVJU9 Serial #: 7009768 15,000 BTU's 19.5 SEER2 - 11.5 EER2 - 9.7 HSPF2 Heating Operation at -13 Degrees & Above *Daikin Wall Mounted Air Handler Model #: FTXV15AVJU9 Serial #: Y000610 Installation: * Additional Services - Electrical Services - Install New Electric to Outdoor Unit * Installation of electric wiring whip & disconnect * Start up and commission new system Warranty: 12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed) 2 Year Westin Air Labor Warranty (Annual maintenance must be performed)


Install Daikin Aurora Ductless System
*Variable Speed Heat Pump:
Model #: RXT15AVJU9
Serial #: 7009768
15,000 BTU's
19.5 SEER2 - 11.5 EER2 - 9.7 HSPF2
Heating Operation at -13 Degrees & Above
*Daikin Wall Mounted Air Handler
Model #: FTXV15AVJU9
Serial #: Y000610

 
Installation:
* Additional Services - Electrical Services - Install New Electric to Outdoor Unit
* Installation of electric wiring whip & disconnect
* Start up and commission new system
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)

Install Daikin Aurora Ductless System
*Variable Speed Heat Pump:
Model #: RXT15AVJU9
Serial #: 7009768
15,000 BTU's
19.5 SEER2 - 11.5 EER2 - 9.7 HSPF2
Heating Operation at -13 Degrees & Above
*Daikin Wall Mounted Air Handler
Model #: FTXV15AVJU9
Serial #: Y000610

 
Installation:
* Additional Services - Electrical Services - Install New Electric to Outdoor Unit
* Installation of electric wiring whip & disconnect
* Start up and commission new system
 
Warranty:
12 Year Daikin manufacturers Parts Warranty (Annual maintenance must be performed)
2 Year Westin Air Labor Warranty (Annual maintenance must be performed)