Full system inspection for new homeowners, heating and cooling run test, duct inspection in the crawlspace. 2012 climate Master TEV038 open loop well system multi-stage communicating geothermal HVAC. 10 kW auxiliary electric resistance heat. All equipment has been serviced and maintained with Westin Air since 2021. The installation, open loop well service, duct modifications, and electrical service was all performed by unknown party's prior to Westin Air Homeowners primary concern is detached ducts in the crawl space for the North great room Test run full system from the communicating ATC thermostat in manual operation mode and confirm all specs and operating parameters in control diagnostic mode. Inspect coil and air filter, water flush drain system, shop vac all equipment inside and out. Test run 10KW auxiliary heat and confirm 40 amps at 241 volts. Inspect coax discharge line for scale build up. Descale flush performed 2021 Several low air coil temperature alerts with the most r