725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for london, oh


Map of London OH
Graham M.

Graham M.


Job Checkin

Gas heating preventative maintenance performed BASEMENT Check filter - 20x25x4 new today shop stock Clean flame sensor Ohm test igniter: 57.2 Inspect wiring for loose connections and/or hot spots - Check humidifier pad: ok - turn hum on 40% Inspect exhaust flu - 2” pvc no concerns Set thermostat for heat Check amp draw on blower motor: 0.63 Check amp draw on inducer motor:3.24 Check delta T - 59° Furnace is in optimal running conditions Gas heating preventative maintenance performed 2ND FLOOR Check filter - 20x25x4 new today shop stock Clean flame sensor Ohm test igniter: 53.4 Inspect wiring for loose connections and/or hot spots - Check humidifier pad: n/a Inspect exhaust flu - 2” PVC no concerns Set thermostat for heat Check amp draw on blower motor: .36 Check amp draw on inducer motor:1.92 Check delta T - 54° Furnace is in optimal running conditions Gas heating preventative maintenance performed GYM Check filter - 20x25x4 new today Clean flame sensor Ohm test igniter: 49.7