725 Kintner Parkway
Sunbury, OH 43074
614-827-1259

Job Locations
for upper arlington, oh


Map of Upper Arlington OH
Graham M.

Graham M.


Job Checkin

Gas heating preventative maintenance performed Check filter - 20x25x4 due soon Clean flame sensor Inspect burners - no concerns Ohm test igniter: 57.3 Inspect wiring for loose connections and/or hot spots - none found Check humidifier pad: n/a Inspect exhaust flu - no concerns Set thermostat for heat Check amp draw on blower motor: 4.21 Check amp draw on inducer motor:0.78 Check delta T - 55° Furnace is in optimal running conditions