Reason for today’s visit with the customer was loss of power on the kitchen counter top. Upon inspection one of the GFCI’s had a neutral terminal that failed and the wire backed itself out. Two of the GFCI’s also on the counter were cracked and due to fail soon due to the age and condition. We recommended replacement of all four GFCI’s located on the counter. The customer requested we correct the wiring on the two recently installed one and then replace the two that were failing as opposed to replacing all four. The customer proceeded with this solution. When we completed the work and went to plug in the fridge it instantly tripped the breaker. we tested continuity in the fridge cord and it rang continuity. We recommended the customer leave the fridge unplugged and suggested repair or replacement before resuming use.