I arrived at our clients home for the unit not cooling properly. I was first led into the home and into the attic. Everything appeared to be working properly and the filter was in good condition. I then went outside and found the outdoor compressor not running. I further diagnosed a failed capacitor to the compressor motor. I did further test the contactor and ensured the system had standing refrigerant. I showed my findings to Mr Adam’s and we discussed the capacitor replacement as well as adding a compressor saver tot he outdoor unit today. Mr Adam’s elected to replace the capacitor only today. Once replaced I further tested and the system to ensure proper operation. I did measure a good 20° drop in the attic. The compressor however is exceeding is manufacturing amp limit. It started up at 166 out of 146 amps today. I did a lite rinse of the outdoor coils to also help the system breathe and operate better. The Freon pressures are a little low. Mr Adam’s is aware this R22 refriger