- Inspection/diagnostics of York/R410A Refrigerant/Split system/Air Handler/Heat Pump. - Homeowners explained how the system wouldn’t keep up to cooling set point of 68°F and how the humidity reading was reading higher than normal. Also showed me alerts/faults displaying at thermostat. - Performed AC diagnostics and found that the air handler motor/module is intermittently failing causing faults and causing pressure switches lockouts on outside equipment. - Was able to determine that when the blower motor is intermittently working the refrigerant charge pressures are within manufacturers specifications. - system has 10 year manufacturer parts warranty & 10 year labor Warranty - filing warranty claim with York manufacturing for blower motor replacement. -recommended to clean/detail/disinfect blower motor wheel during extraction and replacement of motor - Office/dispatch will contact homeowner when we have part availability and to schedule return visit for replacement.