We performed a 3 system cooling maintenance. There are 2 systems are 2023 gas systems. The other system has had a coil replacement but the furnace and outdoor are from 2013. We checked amps, capacitors, filters, electrical, drains, and safeties. These systems are performing decently with some recommended actions. Downstairs 1. The Airscrubber bulb has burnt out. The unit is currently not operating. 2. The outdoor unit is starting with a high load of amps. This strains the contactor, capacitor, and compressor. It is recommended to add a hard start kit to preserve these components for as long as possible. 3. The capacitor is beginning to read weak on the fan side. This is leading to the condenser fan motor to over amp slightly. This will lead to damage and possible failure. Upstairs 1. The outdoor unit is starting with a high load of amps. This strains the contactor, capacitor, and compressor. It is recommended to add a hard start kit to preserve these components for as long as