Provided courtesy call to confirm appointment and verify address. VIP Annual Maintenance Member Today Performed AC Maintenance visit - Provided a demand for cooling at thermostat. - Air distribution motor/assembly/wheel dirty. - 20x25x1 Air Filter clean - Treated drain lines. System draining properly and not retaining water. - performed test on float switch. - Washed/water rinsed outdoor condenser coils. - checked all electrical components/amp draws - refrigerant charge is within manufacturer operating specifications. - system providing a 19-20+°F delta temperature drop across the coil - photo documentation attached - cooling maintenance checklist form filled out and attached. Priority Recommendation: - 7.5 mfd run capacitor for indoor air distribution motor. (Homeowner authorized, replaced on today’s visit.) - System cooling, draining, communicating/functioning properly and at manufacturers specifications upon departure. Additional recommendations. - Compressor saver hard sta