Preformed cooling maintenance on 2020 single system. Upon arrival met homeowner a he front door. Client had no concerns at this moment. I proceeded to the attic, where I tested all electrical components. All tested within manufacturer specifications. I did notice the drain pan to be full of water. I found that the drain line was clogged and backed up into he secondary going into the drain pan. Water is currently draining out of he drain pan to the outside of the home. Temperature across the indoor coil is at 20 degree split. I changed the filter for the client. Size 20x25x1. I proceeded outside to test all electrical components along with run and start amps of the compressor and fan motors. While testing i found that the capacitor and Contactor are testing outside of manufacturer specifications range. I also found that the start amps for the compressor motor was testing over the 75 max amps on the manufacturer specifications range. I did provide estimates for the client to address all