Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed precision gas boiler tune up. Found heat exchanger and smoke pipe to be clear. After talking to homeowner he mentioned that his auto air bleeder would sometimes not bleed the air out correctly. Gave homeowner a quote to replace air bleeder. Cycled on boiler and checked gas pressure and combustion test. Made sure single zone loop was getting hot. Checked operation of circulation pump. 80% gas boiler is functioning fine at time of inspection.