Chris B.

Chris B.


Job Checkin

Performed Precision AC and Heating Tune Up on the Goodman System. Replaced 16x24x1 Air Filter. Cleaned Out all Condensation Drain Lines. While testing Electrical Components, found the Blower Capacitor and the Dual Capacitor we’re testing below rating. When testing Combustion Levels of Furnace found Combustion Levels to be elevated higher than normal. The Furnace was also cycling on/off periodically on High Limit. After further diagnosing the Furnace found the Inducer Motor Assembly was decaying and there was rust present indicating that it was not sealed properly and was leaking. If this is not sealed properly, it could be elevating the Combustion Readings. The Inducer Motor and Assembly would have to be replaced and the system retested. Please note that there still could be further issues with the system, or the system could still experience the High Limit cycling after replacing the Motor. Also spoke with Homeowner about concerns with the Flexible Gas Pipe and the leaking Vent Pipe