Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Arrived to do heating maintenance, went ahead and checked burners, flame sensor, igniter, gas pressure, all electrical connections. Checked amp draw of blower and inducer. Did a combustion analysis. Checked heat exchanger and found cracks on primary and cracks on collector box on the secondary heat exchanger. Recommended replacement or repair. Turned off gas and power switch to unit.