Arrived to assess no heat issue. Found error code history and active error code to be EE0 (Incomplete ignition). Cycled furnace and found that burners were not tinting at all. Removed burners, cleaned burner face surface and in between crossover ports of rust. Tested operations in high fire and low fire. Burners are now lighting across and trial for ignition successfully completing. Also verified inducer draft usuing manometer and flame rectification circuit. Recommend upgrading burners to stainless steel which are now available from manufacturer. Also left estimate to replace burners with equivalent standard burners (not stainless steel; labor only) For the time being burners/furnace is operating well, but burners will become corroded enough again that this can recur.