Run 15 amp circuit from main electrical panel to the kitchen in then basement 15 amp Homeline arc fault breaker for dishwasher they are adding in the future Gfci protected Also from existing outlet on kitchen counter top drop down and add a plug on corner of the wall so the customer can plug in a fridge when they get it We are not responsible for patching and painting any holes we need to make for running the electrical wire I ran a 14-3 wire from main electrical panel to the basement kitchen. I ran the 14-3 wire in case the customer wanted to put the garbage disposal on its own circuit like the code requires they can. Dishwashers and garbage disposals are allowed to share a neutral. I then installed a 1900 box with a gfci and a RS cover plate for the new dishwasher Also i ran a new jumper from a kitchen counter top receptacle to a old work box i cut out next to the cabinets and installed a new tamper resistant receptacle for a new fridge customer will be getting Customer has a