403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for crofton, md


Map of Crofton MD
dennis@haasandsons.com

dennis@haasandsons.com


Job Checkin

Installation of new 2-pole 50 amp breaker to correct current damaged breaker. Breaker was not fully showing 120 voltage to both terminals. After taking breaker out, saw damaged wire on 50 amp circuit from major trip of breaker failure. Installation of whole home surge protector. Surge helps protect the main electrical panel from harmful voltage spikes while protecting the sensitive appliances in the home. Surge reflects lifetime replacement and 60,000.00 warranty.