403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for laurel, md


Map of Laurel MD
Nicholas T.

Nicholas T.


Job Checkin

Reason for today’s visit was to look at an issue with the lights in the house flickering when equipment is turned on. Customer stated that he was having an issue that he recently noticed with lights in the house, flickering more than normal whenever the air conditioning kicks on. I was able to have him turn it on while I had my meter on the main lugs in the panel and found that one of the legs dropped roughly 18 V when the air conditioning was running. Customer has all the appliances in Home that are gas so he has very little load being used. It would appear that there is a loose neutral termination at the power company somewhere outside. I recommended replacing the original split bus panel with a new main breaker panel with all the new code and safety updates. This includes installing whole home surge protection, as well as an emergency disconnect on the outside of the home . I would also recommend installing arc fault protection in areas of the home.

BESbswy