Arrived onsite and the resident led us to the first floor bathroom where she explained when it stormed real bad the other week the bath gfci had went out and never came back. Once we pulled it out to examine it we found power was at that location but the GFCI was bad. Also she had bought a fixture for us to replace out on the deck railing because the old one was hanging and broken. After looking at the area we would be able to hang the light but the switch going to it was bad and had a bad weather seal as well as the outlet below it. I wrote up a few options as well as discussed our membership plan and she opted to get it all done today. We pull the bath gfci out and replaced it. Replaced the light outside on the deck railing, replaced the switch and resealed the box, and then removed the old outlet and installed a w/p gfci and in use cover as well as put silicone around the boxes so they were w/p from the back as well. After we were done the work everything got tested and is verified