403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for riviera beach, md


Map of Riviera Beach MD
Nicholas T.

Nicholas T.


Job Checkin

Reason for today’s visit is to provide pricing and options for installing power for a customers car charger. My first solution is to install a weather existent 50 amp plug on the side of the home roughly 20 foot from the panel in which we will pipe out of the unfinished basement and down the wall. Customer would like us to run a circuit able to handle 100 A so that if he upgrades to the larger 80 amp charger it will already be there. In order to do this we will have to set a weather resistant junction box underneath of the new charger and step the wire down to be able to install The wire on the 50 amp receptacle. The second solution is to run a new 100 amp circuit from the main panel out to a post next to the driveway. The run is roughly 63 feet underground. We will then install a 4 x 4 pressure treated post and install customer supplied charger.