403 Headquarters Dr. Unit 5
Millersville, MD 21108
(443) 396-3797

Job Locations
for severna park, md


Map of Severna Park MD
josh@haasandsons.com

josh@haasandsons.com


Job Checkin

Installation of four six inch recess lights in the main living area as well as four six inch recess lights in the office with dimmers. From the panel we will install two new dedicated circuits in the basement. Both will be 20 Amp Circuits. One will be 10 feet from the panel dedicated only for the treadmill. The other one will be a new circuit for the freezer up to 35 Feet from the panel in the area of the existing HVAC system and Water Heater but we will branch off to two new receptacles as well. One new one will be beside the stairwell, and create a new receptacle in the upstairs main living area adjacent to the main floor stairwell. The other will be in the basement for common usage next to the existing air hockey table in the basement opposite side of the new circuit for the freezer. In the upstairs bathrooms we will install two new Panasonic whisper fans. Finally, we will remove and replace two customer supplied lighting fixtures outdoors.