HVAC Inspection Customer would like heating system evaluated Found clogged flu intake pipe, left intake open and verified heating operation, informed customer that inducer motor is getting hot and may go out during the winter. System is operational
Complaint: No Heat Walking away from this one. Charged $50
Heat Repair - Wiring issue - Found bad igniter and replaced igniter Inducer bearings don't sound good. Thermostat wiring is done the way it is for a reason, presumably some breakage underneath the house, tried two other conductors to no avail. It’s currently a 3 wire set up at the stat with Y and G jumpered at the board. Suggest running new stat wire, furnace running at this time
No heat found bad pressure switch. Ordered new switch, will return with part on Tuesday Returned and replaced pressure switch, inspected flue and inducer motor, system is heating.