Pride Plumbing was called out for no water pressure in the home. Our inspection determined that the issue was being caused by a faulty pressure reducing valve (PRV) at the water meter. We replaced the PRV (attaching it to the existing black roll outside main water supply line with new PEX piping and fittings and adding a ball water shutoff valve and valve box) with a new Watts LFN45BM1-DU-PEXXPEX model. We also provided cost estimates to 1) trench a ditch from the water meter to the home and replace the black roll main outside water supply line with new black roll and PEX piping and fittings along with installing a new pressure reducing valve (PRV) and ball water shutoff valve at the water meter; and 2) replace two leaking outside hose bib spigots with new Woodford frost-free models along with tying them into the existing main water supply line underneath the home with new PEX piping and fittings and adding ball water shutoff valves.