Perform system maintenance on a 2016 Trane 4ton heat pump system unit is level and draining properly. All electrical components documented and cleaned of any debris buildup washed that electronic air filter up in the attic unit is up and running as it should at this time.
Performed 2 system heating maintenance. Checked amps, capacitors, electrical, safeties, cleanliness, and drains. Systems are performing to manufacture specifications with a couple of concerns. Recommendations U/s 1. Emergency pan is compromised and building calcium on the bottom side of the pan. 2. Inducer motor wiring is damaged and can not be effectively repairs. Recommend replacement of the inducer assembly. 3. System does not have a primary float switch to detect clogging before nit becomes a major problem. D/s 1. Blower motor capacitor is reading 6.6 out of 7.5. This is under the rating on the capacitor and I can not guarantee that it will continue to start. 2. Emergency pan is compromised and building calcium on the bottom side of the pan.
Checked systems, adjusted a couple dampers per ms. Washington comfort concerns. Schedule duct cleaning for 2 systems and dryer vent for October 14th. *please call October 13th as reminder for the 14th scheduled cleaning. Additional information on VIP on next visit.